■SPECIFICATIONS AND TEST METHODS
Environment Performance
It shall be soldered on the glass-epoxy substrate.
No
1
Item
Specification
Test Method
1 Cycle
ꢀ 1 step : Minimum Operating Temperature
+0 / -3°C / 30+3 / -0 min
ꢀ 2 step : Room Temperature / within 3 min
ꢀ 3 step : Maximum Operating Temperature
+3 / -0°C / 30 +3 / -0 min
ꢀ 4 step : Room Temperature / within 3 min
Total of 10 cycles
Temperature Cycling Meet Table 4.
Table 4
Appearance
Cap. Change
I.R.
No damaged
Within ±12.5%
Meet the initial rated
value.
DC
Resistance
0.05 max.
Initial values : measured after heat treatment(150+0 / -10°C
,1hour) and exposure in the room condition for 48±4 hours.
Then measured after exposure in the room condition for 48±4
hours.
If it’s doubt, the mesuring has to be done after 1 hours
curing at 150+0 / -10°C and 48±4 hours storage.
2
Humidity
Meet Table 5.
Table 5
Temperature : 40±2°C
Humidity : 90 to 95%(RH)
Time : 500+24 / -0 hours
Appearance
Cap. Change
I.R.
DC
Resistance
No damaged
Within ±12.5%
12.5 F min.
Initial values: measured after heat treatment (150+0 / -10°C ,
1hour) and exposure in the room condition for 48±4 hours.
Then measured after exposure in the room condition for 48±4
hours.
0.05max.
If it ’ s doubt, the mesuring has to be done after 1 hours
curing at 150+0 / -10°C and 48±4 hours storage.
3
Heat Life
Meet Table 6.
Table 6
Temperature : : Maximum Operating Temperature ± 2 °C
Test Voltage : Rated Voltage x 150%
Charge Current : 50 mA max.
Time : 1000+48 / -0 hours
Initial values: measured after heat treatment (150+0 / -10°C ,
1hour) and exposure in the room condition for 48±4 hours.
Then measured after exposure in the room condition for 48±4
hours.
Appearance
Cap. Change
I.R.
DC
Resistance
No damaged
Within ±12.5%
25 F min.
0.05max.
If it’s doubt, the mesuring has to be done after 1 hours curing
at 150+0 / -10°C and 48±4 hours storage.
JEMCPS-03159C
4