■SPECIFICATIONS AND TEST METHODS
Electrical Performance
No
1
Item
Capacitance
Specification
Shown in Rated value.
Test Method
Frequency : 1.0±0.1kHz
Voltage : 0.5V±0.1V(rms)
(Cap.)
Voltage : Rated Voltage
Time : 2 minutes max.
2
Insulation
Resistance(I.R.)
3
4
DC Resistance
Measured with 100mA max.
Withstanding Voltage
Products shall not be damaged.
Shown in Rated value.
Test Voltage : Rated Voltage x 300%
Time : 1 to 5 s
Charge Current : 50 mA max.
Operating Temperature
Storage Temperature
5
6
Includes self-heating
Standard Testing Condition
< Unless otherwise specified >
Temperature : Ordinary Temp. / 15 °C to 35 °C
< In case of doubt >
Temperature: 20 °C ± 2 °C
Humidity: Ordinary Humidity / 25 %(RH) to 85 %(RH) Humidity: 60 %(RH) to 70 %(RH)
Atmospheric pressure: 86 kPa to 106 kPa
JEMCPS-03159C
2