欢迎访问ic37.com |
会员登录 免费注册
发布采购

MT9074AL 参数 Datasheet PDF下载

MT9074AL图片预览
型号: MT9074AL
PDF下载: 下载PDF文件 查看货源
内容描述: T1 / E1 / J1单芯片收发器 [T1/E1/J1 Single Chip Transceiver]
分类和应用: 电信集成电路
文件页数/大小: 122 页 / 371 K
品牌: MITEL [ MITEL NETWORKS CORPORATION ]
 浏览型号MT9074AL的Datasheet PDF文件第92页浏览型号MT9074AL的Datasheet PDF文件第93页浏览型号MT9074AL的Datasheet PDF文件第94页浏览型号MT9074AL的Datasheet PDF文件第95页浏览型号MT9074AL的Datasheet PDF文件第97页浏览型号MT9074AL的Datasheet PDF文件第98页浏览型号MT9074AL的Datasheet PDF文件第99页浏览型号MT9074AL的Datasheet PDF文件第100页  
MT9074  
Advance Information  
Bit  
Name  
Functional Description  
7
TXMSG  
Transmit Message Mode. if high, the data from the corresponding address  
location of Tx message mode buffer is transmitted in the corresponding PCM 30  
time slot. If zero, the data on DSTI is transmitted on the corresponding PCM 30  
time slot.  
6
5
ADI  
Alternate Digit Inversion. If one, the corresponding transmit time slot data on  
DSTI has every second bit inverted. If zero, this bit has no effect on channel data.  
RTSL  
Remote Time Slot Loopback. If one, the corresponding PCM 30 receive time slot  
is looped to the corresponding PCM 30 transmit time slot. This received time slot  
will also be present on DSTO. If zero, the loopback is disabled.  
4
3
LTSL  
TTST  
Local Time Slot Loopback. If one, the corresponding transmit time slot is looped  
to the corresponding receive time slot. This transmit time slot will also be present on  
the transmit PCM 30 stream. If zero, this loopback is disabled.  
Transmit Test. If one, a test signal, either digital milliwatt (when control bit ADSEQ  
15  
is one) or PRBS (2 -1) (ADSEQ is zero), will be transmitted in the corresponding  
PCM 30 time slot. More than one time slot may be activated at once. If zero, the  
test signal will not be connected to the corresponding time slot.  
2
RTST  
Receive Test. If one, the corresponding DSTo time slot will be used for testing. If  
control bit ADSEQ is one, a digital milliwatt signal will be transmitted into the DSTo  
15  
channel. If ADSEQ is zero, the receive channel will be connected to the PRBS (2  
- 1) detector  
1
0
RPSIG  
- - -  
Serial Signaling Enable. If one, the transmit CAS signalling will be controlled by  
programming Page 05H. If zero, the transmit CAS signalling will be controlled  
through the CSTI stream.  
Unused.  
Table 135 - Per Time Slot Control Words (Pages 7 and 8) (E1)  
96  