N25Q128 - 1.8 V
DC and AC parameters
14
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 29. Operating conditions
Symbol
Parameter
Min
Typ
Max
Unit
VCC
VPPH
TA
Supply voltage
1.7
8.5
2
V
V
Supply voltage on VPP
9.5
85
Ambient operating temperature
–40
°C
Table 30. AC measurement conditions
Symbol
Parameter
Min
Max
Unit
Load capacitance
30(1)
pF
ns
V
Input rise and fall times
5
CL
Input pulse voltages
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
VCC / 2
Input timing reference voltages
Output timing reference voltages
V
V
1) Output Buffers are configurable by user.
Figure 107. AC measurement I/O waveform
Input levels
Input and output
timing reference levels
0.8V
CC
0.7V
CC
CC
0.3V
CC
0.5V
0.2V
CC
AI07455
(1)
Table 31. Capacitance
Symbol
Parameter
Test condition
Min
Max
Unit
Input/output capacitance
(DQ0/DQ1/DQ2/DQ3)
CIN/OUT
CIN
VOUT = 0 V
VIN = 0 V
8
6
pF
pF
Input capacitance (other pins)
1. Sampled only, not 100% tested, at TA=25 °C and a frequency of 54 MHz.