512Mb : 32 Me g x 16, 16 Me g x 32 Mo b ile SDRAM
Re g ist e r De fin it io n
Ta b le 4:
Bu rst De fin it io n Ta b le
Ord e r o f Acce sse s Wit h in a Bu rst
Bu rst
Le n g t h
St a rt in g Co lu m n Ad d re ss
Typ e = Se q u e n t ia l
Typ e = In t e rle a ve d
2
A0
0
0-1
1-0
0-1
1-0
1
4
A1
0
A0
0
0-1-2-3
1-2-3-0
2-3-0-1
3-0-1-2
0-1-2-3
1-0-3-2
2-3-0-1
3-2-1-0
0
1
1
0
1
1
8
A2
0
A1
0
A0
0
0-1-2-3-4-5-6-7
1-2-3-4-5-6-7-0
2-3-4-5-6-7-0-1
3-4-5-6-7-0-1-2
4-5-6-7-0-1-2-3
5-6-7-0-1-2-3-4
6-7-0-1-2-3-4-5
7-0-1-2-3-4-5-6
0-1-2-3-4-5-6-7
1-0-3-2-5-4-7-6
2-3-0-1-6-7-4-5
3-2-1-0-7-6-5-4
4-5-6-7-0-1-2-3
5-4-7-6-1-0-3-2
6-7-4-5-2-3-0-1
7-6-5-4-3-2-1-0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
CAS La t e n cy (CL)
The CL is the delay, in clock cycles, between the registration of a READ command and
the availability of the first piece of output data. The latency can be set to two or three
clocks.
If a READ command is registered at clock edge n, and the latency is m clocks, the data
will be available by clock edge n + m. The DQs will start driving as a result of the clock
edge one cycle earlier (n + m - 1), and provided that the relevant access times are met,
the data will be valid by clock edge n + m. For example, assuming that the clock cycle
time is such that all relevant access times are met, if a READ command is registered at T0
and the latency is programmed to two clocks, the DQs will start driving after T1 and the
data will be valid by T2, as shown in Figure 7 on page 16.
Reserved states should not be used as unknown operation or incompatibility with future
versions may result.
Op e ra t in g Mo d e
The normal operating mode is selected by setting M7 and M8 to zero; the other combi-
nations of values for M7 and M8 are reserved for future use.
Reserved states should not be used because unknown operation or incompatibility with
future versions may result.
Writ e Bu rst Mo d e
When M9 = 0, the BL programmed via M0–M2 applies to both READ and WRITE bursts;
when M9 = 1, the programmed BL applies to READ bursts, but write accesses are single-
location accesses.
PDF: 09005aef81ca5de4/Source: 09005aef81ca5e03
MT48H32M16LF_1.fm - Rev. H 6/07 EN
Micron Technology, Inc., reserves the right to change products or specifications without notice.
15
©2005 Micron Technology, Inc. All rights reserved.