M25PX16
DC and AC parameters
10
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 14. Operating conditions
Symbol
Supply Voltage(*)
Min
2.3
Typ
Max
3.6
Unit
VCC
VPPH
TA
Supply Voltage
V
V
Supply Voltage on Vpp
8.5
-40
-40
9.5
Ambient operating temperature (device grade 6)
Ambient operating temperature (device grade 3)
+85
+125
V
TA
°C
Table 15. AC measurement conditions
Symbol
Parameter
Min
Max
Unit
CL
CL
CL
CL
CL
Load capacitance
30
pF
ns
V
Input rise and fall times
5
Input pulse voltages
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
VCC / 2
Input timing reference voltages
Output timing reference voltages
V
V
1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 29. AC measurement I/O waveform
Input levels
Input and output
timing reference levels
0.8V
CC
0.7V
0.5V
0.3V
CC
CC
CC
0.2V
CC
AI07455
(1)
Table 16. Capacitance
Symbol
CIN/OUT Input/output capacitance (DQ0/DQ1)
CIN Input capacitance (other pins)
Parameter
Test condition
Min
Max
Unit
VOUT = 0 V
VIN = 0 V
8
6
pF
pF
1. Sampled only, not 100% tested, at TA=25 °C and a frequency of 33 MHz.
49/65