DC and AC parameters
M25PX16
Unit
Table 17. DC characteristics
Test condition (in addition to those in
Symbol
Parameter
Min
Max
Table 14)
ILI
Input leakage current
Output leakage current
Standby current
± 2
± 2
50
µA
µA
µA
µA
ILO
ICC1
ICC2
S = VCC, VIN = VSS or VCC
S = VCC, VIN = VSS or VCC
Deep Power-down current
10
C = 0.1VCC / 0.9VCC at 75 MHz,
DQ1 = open
12
4
mA
mA
mA
Operating current (READ)
C = 0.1VCC / 0.9VCC at 33 MHz,
DQ1 = open
ICC3
C = 0.1VCC / 0.9VCC at 75 MHz,
DQ1 = open
Operating current (DOFR)
15
Operating current (PP)
Operating current (DIFP)
Operating current (WRSR)
Operating current (SE)
Operating current (BE)
Input low voltage
S = VCC
S = VCC
S = VCC
S = VCC
S = VCC
15
15
15
15
15
mA
mA
mA
mA
mA
ICC4
ICC5
ICC6
ICC7
VIL
– 0.5
0.3VCC
VCC+0.4
0.4
V
V
V
V
VIH
Input high voltage
0.7VCC
VOL
VOH
Output low voltage
IOL = 1.6 mA
Output high voltage
IOH = –100 µA
VCC–0.2
(1)
Table 18. AC characteristics
Test conditions specified in Table 14 and Table 15
Symbol
Alt.
Parameter
Min
Typ(2)
Max
Unit
Clock frequency for the following instructions:
DOFR, DIFP, FAST_READ, SSE, SE, BE, DP,
WREN, WRDI, RDID, RDSR, WRSR, ROTP,
PP, POTP, WRLR, RDLR, RDP
fC
fC
D.C.
75
33
MHz
fR
Clock frequency for READ instructions
D.C.
6
MHz
ns
(3)
tCH
tCLH Clock High time
tCLL Clock Low time
(2)
tCL
6
ns
(4)
tCLCH
Clock rise time(5) (peak to peak)
0.1
0.1
5
V/ns
V/ns
ns
(4)
tCHCL
Clock fall time(5) (peak to peak)
tCSS S active setup time (relative to C)
S not active hold time (relative to C)
tDSU Data In setup time
tSLCH
tCHSL
tDVCH
tCHDX
5
ns
2
ns
tDH
Data In hold time
5
ns
50/65