PIC18F2331/2431/4331/4431
26.4.2
TIMING CONDITIONS
Note: Because of space limitations, the generic
terms “PIC18FXX31” and “PIC18LFXX31”
The temperature and voltages specified in Table 26-3
apply to all timing specifications unless otherwise
noted. Figure 26-4 specifies the load conditions for the
timing specifications.
are used throughout this section to refer to
the PIC18F2331/2431/4331/4431 and
PIC18LF2331/2431/4331/4431 families of
devices specifically, and only those
devices.
TABLE 26-3: TEMPERATURE AND VOLTAGE SPECIFICATIONS – AC
Standard Operating Conditions (unless otherwise stated)
Operating temperature
-40°C TA +85°C for industrial
-40°C TA +125°C for extended
AC CHARACTERISTICS
Operating voltage VDD range as described in DC spec Section 26.1 and
Section 26.3. LF parts operate for industrial temperatures only.
FIGURE 26-4:
LOAD CONDITIONS FOR DEVICE TIMING SPECIFICATIONS
Load Condition 1 Load Condition 2
VDD/2
CL
RL
Pin
VSS
CL
Pin
RL = 464
CL = 50 pF for all pins except OSC2/CLKO
and including D and E outputs as ports
VSS
2010 Microchip Technology Inc.
DS39616D-page 345