 浏览型号LTC2943IDD#PBF的Datasheet PDF文件第12页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第13页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第14页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第15页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第16页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第18页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第19页浏览型号LTC2943IDD#PBF的Datasheet PDF文件第20页  
LTC2943  
APPLICATIONS INFORMATION  
Alert Response Protocol  
SDA pin to see if another device is sending an address at  
2
the same time using standard I C bus arbitration. If the  
Inasystemwhereseveralslavesshareacommoninterrupt  
line, the master can use the alert response address (ARA)  
todeterminewhichdeviceinitiatedtheinterrupt(Figure9).  
LTC2943 is sending a 1 and reads a 0 on the SDA pin on  
the rising edge of SCL, it assumes another device with a  
lower address is sending and the LTC2943 immediately  
aborts its transfer and waits for the next ARA cycle to try  
again. If transfer is successfully completed, the LTC2943  
will stop pulling down the ALCC pin and will not respond  
to further ARA requests until a new Alert event occurs.  
S
ALERT RESPONSE ADDRESS  
0001100  
R
1
A
0
DEVICE ADDRESS  
1100100  
A
P
1
2943 F09  
Figure 9. LTC2943 Serial Bus SDA Alert Response Protocol  
PC Board Layout Suggestions  
Keep all traces as short as possible to minimize noise and  
inaccuracy. Use a 4-wire Kelvin sense connection for the  
sense resistor, locating the LTC2943 close to the resistor  
S ADDRESS W A REGISTER A  
1100100 02h  
S
ADDRESS R A DATA A DATA A  
1100100  
80h 01h 1  
P
0
0
0
1
0
0
2943 F10  
+
with short sense-traces to the SENSE and SENSE pins.  
Use wider traces from the resistor to the battery, load  
Figure 10. Reading the LTC2943 Accumulated Charge  
Registers (C, D)  
+
and/or charger. Put the bypass capacitor close to SENSE  
and GND.  
S ADDRESS W A REGISTER A DATA P  
1100100  
0
0
01h  
0
4C  
TO  
R
TO BATTERY  
SENSE  
CHARGER/LOAD  
40ms  
8
7
6
5
1
2
3
4
S ADDRESS W A REGISTER A  
1100100 08h  
S
ADDRESS R A DATA A DATA A  
1100100  
F1h 80h 1  
P
C
0
0
0
1
0
0
LTC2943  
2943 F11  
Figure 11. ADC Single Conversion Sequence and Reading  
of Voltage Registers (I,J)  
2943 F12  
The master initiates the ARA procedure with a START  
conditionandthespecial7-bitARAbusaddress(0001100)  
followed by the read bit (R) = 1. If the LTC2943 is as-  
serting the ALCC pin in alert mode, it acknowledges and  
responds by sending its 7-bit bus address (1100100)  
and a 1. While it is sending its address, it monitors the  
Figure 12. Kelvin Connection on Sense Resistor  
2943fa  
17  
For more information www.linear.com/LTC2943  