Specifications ispLSI and pLSI 1032
1
Absolute Maximum Ratings
Supply Voltage V ...................................-0.5 to +7.0V
cc
Input Voltage Applied........................ -2.5 to V +1.0V
CC
Off-State Output Voltage Applied ..... -2.5 to V +1.0V
CC
Storage Temperature................................ -65 to 150°C
Case Temp. with Power Applied .............. -55 to 125°C
Max. Junction Temp. (T ) with Power Applied ... 150°C
J
1. Stresses above those listed under the “Absolute Maximum Ratings” may cause permanent damage to the device. Functional
operation of the device at these or at any other conditions above those indicated in the operational sections of this specification
is not implied (while programming, follow the programming specifications).
DC Recommended Operating Conditions
SYMBOL
PARAMETER
MIN.
MAX.
5.25
5.5
UNITS
Commercial TA = 0°C to +70°C
4.75
4.5
4.5
0
Supply Voltage
V
V
V
CC
Industrial
TA = -40°C to +85°C
TC = -55°C to +125°C
Military/883
5.5
Input Low Voltage
Input High Voltage
V
V
IL
0.8
IH
V
2.0
Vcc + 1
Table 2- 0005Aisp w/mil.eps
Capacitance (TA=25oC, f=1.0 MHz)
1
SYMBOL PARAMETER
MAXIMUM
UNITS
TEST CONDITIONS
C1
Commercial/Industrial
Military
8
pf
VCC=5.0V, VIN=2.0V
Dedicated Input Capacitance
10
10
pf
pf
VCC=5.0V, VIN=2.0V
C2
I/O and Clock Capacitance
VCC=5.0V, VI/O, VY=2.0V
Table 2- 0006
1. Guaranteed but not 100% tested.
Data Retention Specifications
PARAMETER
Data Retention
MINIMUM
20
MAXIMUM
UNITS
Years
–
–
–
ispLSI Erase/Reprogram Cycles
pLSI Erase/Reprogram Cycles
10000
100
Cycles
Cycles
Table 2- 0008B
3