 浏览型号TE28F160C3BA90的Datasheet PDF文件第26页浏览型号TE28F160C3BA90的Datasheet PDF文件第27页浏览型号TE28F160C3BA90的Datasheet PDF文件第28页浏览型号TE28F160C3BA90的Datasheet PDF文件第29页浏览型号TE28F160C3BA90的Datasheet PDF文件第31页浏览型号TE28F160C3BA90的Datasheet PDF文件第32页浏览型号TE28F160C3BA90的Datasheet PDF文件第33页浏览型号TE28F160C3BA90的Datasheet PDF文件第34页  
£
Intel Advanced+ Boot Block Flash Memory (C3)  
5.5.1  
5.5.2  
Reading the Protection Register  
The protection register is read in the read-identifier mode. The device is switched to this mode by  
issuing the Read Identifier command (0x90). Once in this mode, read cycles from addresses shown  
in Figure 6, “Protection Register Mapping” retrieve the specified information. To return to read-  
array mode, issue the Read Array command (0xFF).  
Programming the Protection Register  
The protection register bits are programmed using the two-cycle Protection Program command.  
The 64-bit number is programmed 16 bits at a time. First, issue the Protection Program Setup  
command, 0xC0. The next write to the device will latch in address and data, and program the  
specified location. The allowable addresses are shown in Table 6, “Device Identification Codes” on  
page 20. See Figure 18, “Protection Register Programming Flowchart” on page 57. Attempts to  
address Protection Program commands outside the defined protection register address space should  
not be attempted. Attempting to program to a previously locked protection register segment will  
result in a Status Register error (Program Error bit SR[4] and Lock Error bit SR[1] will be set to 1).  
5.5.3  
Locking the Protection Register  
The user-programmable segment of the protection register is lockable by programming bit 1 of the  
PR-LOCK location to 0. See Figure 6, “Protection Register Mapping” on page 30. Bit 0 of this  
location is programmed to 0 at the Intel factory to protect the unique device number. This bit is set  
using the Protection Program command to program 0xFFFD to the PR-LOCK location. After these  
bits have been programmed, no further changes can be made to the values stored in the protection  
register. Protection Program commands to a locked section will result in a Status Register error  
(Program Error bit SR[4] and Lock Error bit SR[1] will be set to 1). Protection register lockout  
state is not reversible.  
Figure 6. Protection Register Mapping  
0x88  
64-bit Segment  
(User-Programmable)  
0x85  
0x84  
128-Bit Protection Register 0  
64-bit Segment  
(Intel Factory-Programmed)  
0x81  
0x80  
PR Lock Register 0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
5.6  
VPP Program and Erase Voltages  
The C3 device provides in-system programming and erase in the 1.65 V–3.6 V range. For fast  
production programming, 12 V programming can be used. Refer to Figure 7, “Example Power  
Supply Configurations” on page 31.  
30  
Datasheet