 浏览型号TE28F128J3C-150的Datasheet PDF文件第63页浏览型号TE28F128J3C-150的Datasheet PDF文件第64页浏览型号TE28F128J3C-150的Datasheet PDF文件第65页浏览型号TE28F128J3C-150的Datasheet PDF文件第66页浏览型号TE28F128J3C-150的Datasheet PDF文件第68页浏览型号TE28F128J3C-150的Datasheet PDF文件第69页浏览型号TE28F128J3C-150的Datasheet PDF文件第70页浏览型号TE28F128J3C-150的Datasheet PDF文件第71页  
256-Mbit J3 (x8/x16)  
Figure 26. Protection Register Programming Flowchart  
Start  
Bus Operation  
Command  
Comments  
Protection Program  
Setup  
Write  
Write  
Data = C0H  
Write C0H  
(Protection Reg.  
Program Setup)  
Data = Data to Program  
Addr = Location to Program  
Protection Program  
Status Register Data Toggle  
CE# or OE# to Update Status  
Register Data  
Write Protect. Register  
Address/Data  
Read  
Check SR.7  
Standby  
1 = WSM Ready  
0 = WSM Busy  
Read Status Register  
Protection Program operations can only be addressed within the protection  
register address space. Addresses outside the defined space will return an  
error.  
No  
SR.7 = 1?  
Yes  
Repeat for subsequent programming operations.  
SR Full Status Check can be done after each program or after a sequence of  
program operations.  
Full Status  
Check if Desired  
Write FFH after the last program operation to reset device to read array mode.  
Program Complete  
FULL STATUS CHECK PROCEDURE  
Bus Operation  
Standby  
Command  
Comments  
SR.1 SR.3 SR.4  
Read Status Register  
Data (See Above)  
0
1
1
V PEN Low  
1, 1  
0
0
1
Prot. Reg.  
Prog. Error  
Standby  
SR.3, SR.4 =  
SR.1, SR.4 =  
VPEN Range Error  
1
0
1
Register  
Locked:  
Aborted  
0,1  
1,1  
Standby  
Protection Register  
Programming Error  
SR.3 MUST be cleared, if set during a program attempt, before further  
attempts are allowed by the Write State Machine.  
Attempted Program to  
Locked Register -  
Aborted  
SR.1, SR.3 and SR.4 are only cleared by the Clear Staus Register Command,  
in cases of multiple protection register program operations before full status is  
checked.  
SR.1, SR.4 =  
If an error is detected, clear the status register before attempting retry or other  
error recovery.  
Program Successful  