A
80960JD
Table 14. 80960JD ICC Characteristics
Symbol
Parameter
Typ
Max
Units
Notes
ILI1
Input Leakage Current for
each pin except TCK, TDI,
TRST and TMS
± 1
mA
0 £ VIN £ VCC
ILI2
ILO
Input Leakage Current for
TCK, TDI, TRST and TMS
-140
-250
± 1
mA
VIN = 0.45V (1)
Output Leakage Current
mA
0.4 £ VOUT £ VCC
ICC Active
(Power Supply)
80960JD-50
80960JD-40
80960JD-33
640
530
450
mA
(2,3)
(2,3)
(2,3)
ICC Active
(Thermal)
80960JD-50
80960JD-40
80960JD-33
525
430
365
mA
mA
(2,4)
(2,4)
(2,4)
ICC Test
(Power modes)
Reset mode
80960JD-50
80960JD-40
80960JD-33
510
430
370
(5)
(5)
(5)
Halt mode
80960JD-50
80960JD-40
80960JD-33
48
41
36
(5)
(5)
(5)
ONCE mode
10
(5)
NOTES:
1. These pins have internal pullup devices. Typical leakage current is not tested.
2. Measured with device operating and outputs loaded to the test condition in Figure 8, AC Test Load (pg.
33).
3. ICC Active (Power Supply) value is provided for selecting your system’s power supply. It is measured
using one of the worst case instruction mixes with V
tested.
= 5.25V. This parameter is characterized but not
CC
4. ICC Active (Thermal) value is provided for your system’s thermal management. Typical ICC is measured
with VCC = 5.0V and temperature = 25° C. This parameter is characterized but not tested.
5. ICC Test (Power modes) refers to the ICC values that are tested when the 80960JD is in Reset mode,
Halt mode or ONCE mode with V
= 5.25V.
CC
25