Functional Description  
5.11  
Real Time Clock (D31:F0)  
The Real Time Clock (RTC) module provides a battery backed-up date and time keeping  
device with two banks of static RAM with 128 bytes each, although the first bank has  
114 bytes for general purpose usage. Three interrupt features are available: time of  
day alarm with once a second to once a month range, periodic rates of 122 µs to  
500 ms, and end of update cycle notification. Seconds, minutes, hours, days, day of  
week, month, and year are counted. Daylight savings compensation is no longer  
supported. The hour is represented in twelve or twenty-four hour format, and data can  
be represented in BCD or binary format. The design is functionally compatible with the  
Motorola MS146818B. The time keeping comes from a 32.768 kHz oscillating source,  
which is divided to achieve an update every second. The lower 14 bytes on the lower  
RAM block has very specific functions. The first ten are for time and date information.  
The next four (0Ah to 0Dh) are registers, which configure and report RTC functions.  
The time and calendar data should match the data mode (BCD or binary) and hour  
mode (12 or 24 hour) as selected in register B. It is up to the programmer to make  
sure that data stored in these locations is within the reasonable values ranges and  
represents a possible date and time. The exception to these ranges is to store a value  
of C0–FFh in the Alarm bytes to indicate a don’t care situation. All Alarm conditions  
must match to trigger an Alarm Flag, which could trigger an Alarm Interrupt if enabled.  
The SET bit must be 1 while programming these locations to avoid clashes with an  
update cycle. Access to time and date information is done through the RAM locations. If  
a RAM read from the ten time and date bytes is attempted during an update cycle, the  
value read do not necessarily represent the true contents of those locations. Any RAM  
writes under the same conditions are ignored.  
Note:  
The leap year determination for adding a 29th day to February does not take into  
account the end-of-the-century exceptions. The logic simply assumes that all years  
divisible by 4 are leap years. According to the Royal Observatory Greenwich, years that  
are divisible by 100 are typically not leap years. In every fourth century (years divisible  
by 400, like 2000), the 100-year-exception is over-ridden and a leap-year occurs. Note  
that the year 2100 will be the first time in which the current RTC implementation would  
incorrectly calculate the leap-year.  
The ICH10 does not implement month/year alarms.  
5.11.1  
Update Cycles  
An update cycle occurs once a second, if the SET bit of register B is not asserted and  
the divide chain is properly configured. During this procedure, the stored time and date  
are incremented, overflow is checked, a matching alarm condition is checked, and the  
time and date are rewritten to the RAM locations. The update cycle will start at least  
488 µs after the UIP bit of register A is asserted, and the entire cycle does not take  
more than 1984 µs to complete. The time and date RAM locations (0–9) are  
disconnected from the external bus during this time.  
To avoid update and data corruption conditions, external RAM access to these locations  
can safely occur at two times. When a updated-ended interrupt is detected, almost 999  
ms is available to read and write the valid time and date data. If the UIP bit of Register  
A is detected to be low, there is at least 488 µs before the update cycle begins.  
Warning:  
The overflow conditions for leap years adjustments are based on more than one date or  
time item. To ensure proper operation when adjusting the time, the new time and data  
values should be set at least two seconds before leap year occurs.  
Datasheet  
135  