DDR MemBIST  
Failure addresses are logged in a slightly different format than the format which is used  
when specifying start and end addresses. To compress the failure address into 32 bits,  
bits that are always zero are not stored in the log. These unstored bits include  
AutoPrecharge Column address [10] and the least significant bits assumed by burst  
length. In BL=4 operation, column bit 1 in the log is replaced by a bit which  
distinguishes whether the error was detected in the first 144-bit data chunk (the bit is  
0) or in the second chunk (the bit is 1). In like manner, for BL=8 operation, column  
bits 2:1 are replaced by two bits to identify the data chunk containing the error. The  
bits used for BL=8 are shaded in Table 11-8 below. See Section 14.5.2.3.1, “MBDATA  
Failure Address Mapping” for more information.  
Table 11-8. Address Log to Bank, Row and Column Bit Correspondence  
Address Log Register Bit  
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10  
9
8
9
7
8
6
7
5
6
4
5
3
4
2
3
1
2
0
1
2
1
0
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
14 13 12 11  
Bank  
Row  
Column  
11.3.5.3  
Failure Data Bit Location Accumulator  
MemBIST provides a (sometimes optional) 144-bit failure data bit location accumulator,  
maintained in the MBDATA registers. Each bit tracks a data bit during MemBIST  
operation. This accumulator is automatically zeroed each time that MemBIST starts  
execution of a new operation.  
An accumulator bit set to 1 indicates that the corresponding data bit failed to have the  
expected value at least once during the operation. This accumulator is used primarily  
for recording detected failed data lines to facilitate DRAM replacement during DIMM  
manufacturing.  
Table 11-9 below shows the correspondence between the DRAM data bus bits and the  
160 bits in the MBDATA registers used to store the failure data bit location accumulator.  
Table 11-9. Failure Data Bit Location Accumulator to MBDATA Bit Correspondence  
MBDATA[8]  
MBDATA[3]  
MBDATA[2]  
MBDATA[1]  
MBDATA[0]  
31  
24  
23  
16  
15  
71  
8
7
0
31  
63  
0
31  
31  
0
31  
63  
0
31  
31  
0
Unused  
64  
71  
64  
32  
0
32  
0
Late data  
Early data  
Late data  
Late data  
Early data  
Early data  
11.3.5.4  
Failure Data Logging  
Failure data is logged in the MB_ERR_DATA registers. These data logging registers are  
not cleared when MemBIST starts execution of a new operation, although the  
corresponding address logs in the MBDATA registers are cleared. The user desiring to  
discard failure data logs from a previous operation must write zeros to these registers  
before starting the next operation. During execution of a subsequent operation, when  
the first failure is detected, both an address and a data log are written, beginning with  
the first error log entry. Any existing data in the data logging registers used for this log  
entry is overwritten. The data in the other data logging registers is not affected.  
Table 11-10 shows the correspondence between the failure number, the address log for  
this error, and the data log for this error. Which register is used to log the address of  
the failure depends upon settings in MBCSR:dtype and MBCSR:algo. If MBCSR:algo is  
non-zero, then an algorithm is selected, and fixed data is used. Address logging will  
occur according to the “Fixed data pattern” entries in Table 11-10.  