XC835/836
Electrical Parameters
3.3.2
Output Rise/Fall Times
Table 18 provides the characteristics of the output rise/fall times in the XC835/836.
Table 18
Parameter
Output Rise/Fall Times Parameters (Operating Conditions apply)
Symbol Limit Values Unit Test Conditions
Min.
Max.
Rise/fall times on High
Current Pad Type A1)2)
tHCPR
tHCPF
,
–
–
–
–
–
–
15
ns
ns
ns
ns
ns
ns
20 pF @ Fast edge
(5 V) 3).
150
25
20 pF @ Slow Edge
(5 V)3).
20 pF @ Fast edge
(3.3 V)4).
300
10
20 pF @ Slow edge
(3.3 V)4).
Rise/fall times on High
Current Pad Type B1)2)
tR, tF
tR, tF
20 pF3)4)
(5 V & 3.3 V).
Rise/fall times on
10
20 pF3)4)
Standard Pad1)2)
(5 V & 3.3 V).
1) Rise/Fall time parameters are taken with 10% - 90% of supply.
2) Not all parameters are 100% tested, but are verified by design/characterisation and test correlation.
3) Additional rise/fall time valid for CL = 20 pF - CL = 100 pF @ 0.125 ns/pF at 5 V supply voltage.
4) Additional rise/fall time valid for CL = 20 pF - CL = 100 pF.@ 0.225 ns/pF at 3.3 V supply voltage.
V
DDC
90%
90%
10%
10%
V
SS
t
t
F
R
Figure 14
Rise/Fall Times Parameters
Data Sheet
39
V1.2, 2011-03