TC39x BC/BD-Step
Electrical Specification5 V / 3.3 V switchable Pads
Table 3-7 Fast 5V GPIO (cont’d)
Parameter
Symbol
Values
Typ.
Unit
Note / Test Condition
Min.
Max.
Input leakage current
I
OZ CC
-1100
-
1100
nA
TJ ≤ 150°C ; (0.1 *
VEXT/FLEX/EVRSB) < VIN <
(0.9 * VEXT/FLEX/EVRSB
)
-2500
-
2500
nA
TJ ≤ 150°C ; (0.1 *
V
V
EXT/FLEX) < VIN < (0.9 *
EXT/FLEX) ; LVDS_TX /
Fast pad type
-6000
-3200
-
-
6000
3200
nA
nA
TJ ≤ 150°C ; LVDS_RX
/ Fast pad type ; else
TJ ≤ 150°C ; LVDS_TX
/ Fast pad type ; else
-1500
-2000
-
-
1500
2000
nA
nA
TJ ≤ 150°C ; else
TJ ≤ 170°C ; (0.1 *
VEXT/FLEX/EVRSB) < VIN <
(0.9 * VEXT/FLEX/EVRSB
)
-4000
-
4000
nA
TJ ≤ 170°C ; (0.1 *
V
V
EXT/FLEX) < VIN < (0.9 *
EXT/FLEX) ; LVDS_TX /
Fast pad type
-13500
-5100
-2500
-
-
13500
5100
nA
nA
TJ ≤ 170°C ; LVDS_RX
/ Fast pad type ; else
TJ ≤ 170°C ; LVDS_TX
/ Fast pad type ; else
-
-
2500
-
nA
V
TJ ≤ 170°C ; else
Input high voltage level
Input low voltage level
VIH SR
VIL SR
0.7 *
AL
VEXT/FLEX/E
VRSB
2.0
-
-
-
V
V
TTL
AL
-
0.44 *
VEXT/FLEX/E
VRSB
-
-
-
0.8
V
TTL
Input low threshold variation
Pin capacitance
V
ILD SR
-50
50
mV
max. variation of 1ms;
VEXT/FLEX/EVRSB
constant; AL
=
CIO CC
SET CC
-
-
2
-
3
pF
ns
in addition 2.5pF from
package to be added
Pad set-up time to get an
software update of the
configuration active
t
100
1) In the formulas the value of CL needs to be entered in pF to obtain results in ns.
2) Rise / fall times are defined 10% - 90% of pad supply voltage.
Data Sheet
415
V 1.2, 2021-03
OPEN MARKET VERSION