PEB 2091
PEF 2091
Operational Description
Data
During normal operation (i.e. transparent transmission and no test mode) the 2B+D
channels can be accessed via the IOM®-2 or the µP interface, if used. See section 4.2.1,
page 108 for details.
EOC
Basically the EOC channel can be accessed via MON-0 messages. However, internal
processing, manipulation and filtering of the EOC messages could take place
automatically, depending on the mode chosen. For details see section 4.2.2, page 110.
U Basic Frame
1.5 ms
Receiver
Data
(From U)
Data
12x (2B+D)
216 Bits
(I)SW
Fixed
18 Bits
M5-M6
2 Bit
M4
1 Bit
M1-M3
3 Bits
Time
Receiver
FIFO
2B+D1)
EOC
Processor
MON-01)
MON-11)
MON-21)
Single Bits
Processor
CRC2)
Processor
1) To IOM®-2 and µP (if used)
2) CRC bits not accessable to user
Figure 45
Channels of Access to U-Interface (Receiver)
Semiconductor Group
107