Register Description  
4.1.9  
Extended Interrupt Register  
EXIR  
Read  
Address 24  
H
Value after reset: 00  
H
7
0
XMR  
XDU  
PCE  
RFO  
SOV  
MOS  
SAW WOV  
XMR  
XDU  
Transmit Message Repeat  
The transmission of the last frame has to be repeated because:  
– the ISAC-S has received a negative acknowledgement to an I-frame in auto-mode  
(according to HDLC/LAPD)  
– or a collision on the S-bus has been detected after the 32nd data byte of a transmit  
frame.  
Transmit Data Underrun  
The current transmission of a frame is aborted by transmitting seven "1's" because  
the XFIFO holds no further data. This interrupt occurs whenever the processor has  
failed to respond to an XPR interrupt (ISTA register) quickly enough, after having  
initiated a transmission and the message to be transmitted is not yet complete.  
Note: When an XMR or and XDU interrupt is generated, it is not possible to send  
transparent frames or I-frames until the interrupt has been acknowledged by reading  
EXIR.  
PCE  
Protocol Error  
Used in auto-mode only.  
A protocol error has been detected in auto-mode due to a received  
– S- or I-frame with an incorrect sequence number N(R) or  
– S-frame containing an I-field.  
I-frame which is not a command.  
– S-frame with an undefined control field.  
Receive Frame Overflow  
RFO  
The received data of a frame could not be stored, because the RFIFO is occupied.  
The whole message is lost.  
This interrupt can be used for statistical purposes and indicates that the processor  
does not respond quickly enough to an RPF or RME interrupt (ISTA).  
SOV  
MOS  
Synchronous Transfer Overflow  
The synchronous transfer programmed in STCR has not been acknowledged in time  
via the SC0/SC1 bit.  
MONITOR Status  
A change in the MONITOR Status Register (MOSR) has occured (IOM-2).  
A new MONITOR channel byte is stored in MOR (IOM-1).  
Semiconductor Group  
209  