Functional Description  
3.7.3.2  
Auto Restart without extended blanking a trigger signal to the base of the externally added  
time  
transistor, TAE at the BA pin. When the function is  
enabled, the gate drive switching will be stopped and  
then the IC will enter auto-restart mode if the signal  
persists. To ensure this auto-restart function will not be  
mis-triggered during start up, a 1ms delay time is  
implemented to blank the unstable signal.  
AutoRestart  
Mode Reset  
VVCC < 10.5V  
1ms  
UVLO  
VCC undervoltage is the Vcc voltage drop below Vcc  
turn off threshold. Then the IC will turn off and the start  
up cell will turn on automatically. And this leads to Auto  
Restart Mode.  
Short Optocoupler also leads to VCC undervoltage.  
When the FB pin is pulled low, there is no switching  
pulse. Then the Vcc will drop to Vcc turn off threshold.  
And it leads to Auto Restart Mode.  
counter  
BA  
Auto-restart  
Enable  
Signal  
Stop  
gate  
drive  
C9  
0.33V  
AutoRestart  
mode  
25.5V  
VCC  
T
AE  
120us  
Blanking  
Time  
C2  
Spike  
VCC  
&
Blanking  
C1  
C4  
20.7V  
30us  
G1  
softs_period  
4.5V  
Voltage  
FB  
Thermal Shutdown  
Reference  
T >130°C  
j
Control Unit  
Figure 26  
Auto Restart mode  
There are 2 modes of VCC overvoltage protection; one  
is during soft start and the other is at all conditions.  
The first one is VVCC voltage is > 20.7V and FB is > 4.5V  
and during soft_start period. The IC enters Auto  
Restart Mode. The VCC voltage is observed by  
comparator C1. This fault condition is to detect the  
abnormal operating during start up such as open loop  
during light load start up, etc. The logic can eliminate  
the possible of entering Auto Restart mode if there is a  
small voltage overshoots of VVCC during normal  
operating.  
The 2nd one is VVCC >25.5V and last for 120us and the  
IC enters Auto Restart Mode. This 25.5V Vcc OVP  
protection is inactivated during burst mode.  
The Thermal Shutdown block monitors the junction  
temperature of the IC. After detecting a junction  
temperature higher than 130°C, the Auto Restart Mode  
is entered.  
In case the pre-defined auto-restart features are not  
sufficient, there is a customer defined external Auto-  
restart Enable feature. This function can be triggered  
by pulling down the BA pin to < 0.33V. It can simply add  