CoolSET™-F3  
Functional Description  
via the gate G2. The external Soft Start capacitor can The Active Burst Mode is located in the Control Unit.  
now be charged further by the integrated pull up Figure 17 shows the related components.  
resistor RSoftS. The comparator C3 releases the gates  
G5 and G6 once VSofts has exceeded 5.4V. Therefore 3.6.2.1  
Entering Active Burst Mode  
there is no entering of Auto Restart Mode possible  
The FB signal is always observed by the comparator  
C5 if the voltage level falls below 1.32V. In that case the  
switch S1 is released which allows the capacitor CSoftS  
to be charged starting from the clamped voltage level  
at 4.4V in normal operating mode. If VSoftS exceeds  
5.4V the comparator C3 releases the gate G6 to enter  
the Active Burst Mode. The time window that is  
generated by combining the FB and SoftS signals with  
gate G6 avoids a sudden entering of the Active Burst  
Mode due to large load jumps. This time window can be  
during this charging time of the external capacitor  
SoftS. The same procedure happens to the external  
C
Soft Start capacitor if a low load condition is detected  
by comparator C5 when VFB is falling below 1.32V.  
Only after VSoftS has exceeded 5.4V and VFB is still  
below 1.32V Active Burst Mode is entered.  
3.6.2  
The controller provides Active Burst Mode for low load  
conditions at VOUT Active Burst Mode increases  
Active Burst Mode  
adjusted by the external capacitor CSoftS  
.
.
significantly the efficiency at light load conditions while  
supporting a low ripple on VOUT and fast response on  
load jumps. During Active Burst Mode which is  
controlled only by the FB signal the IC is always active  
and can therefore immediately response on fast  
changes at the FB signal. The Startup Cell is kept  
switched off to avoid increased power losses for the  
self supply.  
After entering Active Burst Mode a burst flag is set and  
the internal bias is switched off in order to reduce the  
current consumption of the IC down to approx. 1.05mA.  
In this Off State Phase the IC is no longer self supplied  
so that therefore CVCC has to provide the VCC current  
(see Figure 18). Furthermore gate G11 is then released  
to start the next burst cycle once VFB has 3.4V  
exceeded.  
It has to be ensured by the application that the VCC  
remains above the Undervoltage Lockout Level of 8.5V  
to avoid that the Startup Cell is accidentally switched  
on. Otherwise power losses are significantly increased.  
The minimum VCC level during Active Burst Mode is  
depending on the load conditions and the application.  
The lowest VCC level is reached at no load conditions  
SoftS  
6.5V  
RSoftS  
5k?  
Internal Bias  
4.4V  
at VOUT  
.
3.6.2.2  
Working in Active Burst Mode  
S1  
Current  
After entering the Active Burst Mode the FB voltage  
rises as VOUT starts to decrease due to the inactive  
PWM section. Comparator C6a observes the FB signal  
if the voltage level 4V is exceeded. In that case the  
internal circuit is again activated by the internal Bias to  
start with switching. As now in Active Burst Mode the  
gate G10 is released the current limit is only 0.257V to  
reduce the conduction losses and to avoid audible  
noise. If the load at VOUT is still below the starting level  
for the Active Burst Mode the FB signal decreases  
down to 3.4V. At this level C6b deactivates again the  
internal circuit by switching off the internal Bias. The  
gate G11 is released as after entering Active Burst  
Mode the burst flag is set. If working in Active Burst  
Mode the FB voltage is changing like a saw tooth  
between 3.4V and 4V (see Figure 18).  
Limiting  
&
C3  
G10  
5.4V  
4.8V  
C4  
Active  
Burst  
C5  
&
G6  
Mode  
FB  
1.32V  
4.0V  
3.4V  
C6a  
C6b  
3.6.2.3  
Leaving Active Burst Mode  
&
The FB voltage immediately increases if there is a high  
load jump. This is observed by comparator C4. As the  
current limit is ca. 26% during Active Burst Mode a  
certain load jump is needed that FB can exceed 4.8V.  
At this time C4 resets the Active Burst Mode which also  
G11  
Control Unit  
Figure 18  
Active Burst Mode  
Version 1.3  
16  
15 Sep 2004  