CoolSET™-F3  
Functional Description  
blocks C12 by the gate G10. Maximum current can now 3.6.3  
Protection Mode (Auto Restart Mode)  
be provided to stabilize VOUT  
.
In order to increase the SMPS system’s robustness  
and safety, the IC provides the Auto Restart Mode as a  
protection feature. The Auto Restart Mode is entered  
upon detection of the following faults in the system:  
V
FB  
Entering Active  
Burst Mode  
Leaving Active  
Burst Mode  
VCC Overvoltage  
Overtemperature  
Overload  
Open Loop  
VCC Undervoltage  
Short Optocoupler  
4.80V  
4.00V  
3.40V  
1.32V  
VSoftS  
t
Blanking Window  
SoftS  
6.5V  
Control Unit  
RSoftS  
5.40V  
CSoftS  
5k  
VCC  
4.40V  
C1  
&
G1  
4.4V  
Spike  
17V  
Blanking  
VCS  
t
t
t
t
t
8.0us  
C11  
4.0V  
Thermal Shutdown  
T >140°C  
j
Current limit level during  
Active Burst Mode  
1.00V  
S1  
0.257V  
4.8V  
5.4V  
&
Auto Restart  
Mode  
C4  
C3  
FB  
V
G5  
VCC  
Voltage  
Reference  
8.5V  
Figure 20  
Auto Restart Mode  
The VCC voltage is observed by comparator C1 if 17V  
is exceeded. The output of C1 is combined with both  
the output of C11 which checks for SoftS<4.0V, and the  
output of C4 which checks for FB>4.8V. Therefore the  
overvoltage detection is can only active during Soft  
Start Phase(SoftS<4.0V) and when FB signal is  
outside the operating range > 4.8V. Therefore any  
small voltage overshoots of VVCC during normal  
operating cannot trigger the Auto Restart Mode.  
IVCC  
7.2mA  
1.05mA  
VOUT  
In order to ensure system reliability and prevent any  
false activation, a blanking time is implemented before  
the IC can enter into the Auto Restart Mode. The output  
of the VCC overvoltage detection is fed into a spike  
blanking with a time constant of 8.0µs.  
Max. Ripple < 1%  
The other fault detection which can result in the Auto  
Restart Mode and has this 8.0µs blanking time is the  
Overtemperature detection. This block checks for a  
junction temperature of higher than 140°C for  
malfunction operation.  