BTS 3410 G
Maximum Ratings at T = 25°C, unless otherwise specified
Parameter
Drain source voltage
Drain source voltage for short circuit protection
Symbol
Value
42
18
Unit
V
V
V
DS
1)
DS(SC)
T = -40...150 °C
Continuous input current
j
1)
I
mA
IN
-0.2V ? V ? 10V
no limit
IN
V < -0.2V or V > 10V
| I | ? 2
IN
IN
IN
°C
W
mJ
V
Operating temperature
Storage temperature
Power dissipation
T
-40 ...+150
-55 ... +150
0.8
T
2)5)
P
E
V
tot
T = 85 °C
A
1)
Unclamped single pulse inductive energy
each channel
Load dump protection V
150
50
AS
LD
1)3)
= V + V
A S
LoadDump
V = 0 and 10 V, td = 400 ms, R = 2 ꢀ,
IN
I
R = 9 ꢀ, V = 13.5 V
L
A
1)
2
kV
Electrostatic discharge voltage (Human Body Model) V
according to Jedec norm
ESD
EIA/JESD22-A114-B, Section 4
MSL1
Jedec humidity category,J-STD-20-B
IEC climatic category; DIN EN 60068-1
40/150/56
Thermal resistance
junction - ambient: per channel
R
K/W
thJA
2
2)
@ 6 cm cooling area
one channel on
100
160
both channels on
1
2
not subject to production test, specified by design
Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm
2 (one layer, 70µm thick) copper area for drain
connection. PCB mounted vertical without blown air.
3
V
is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839
Loaddump
5
not subject to production test, calculated by R
and R
ds(on)
THJA
Page 3
2004-03-05