IDT7132SA/LA and IDT 7142SA/LA
High Speed 2K x 8 Dual Port Static RAM
Military, Industrial and Commercial Temperature Ranges
AC Electrical Characteristics Over the
Operating Temperature Supply Voltage Range(5,6)
7132X20(2)
7142X20(2)
Com'l Only
7132X25(2)
7142X25(2)
Com'l, Ind
& Military
7132X35
7142X35
Com'l &
Military
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Unit
WRITE CYCLE
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
____
t
WC
EW
AW
AS
WP
WR
DW
HZ
DH
WZ
OW
Write Cycle Time(3)
20
15
15
0
25
20
20
0
35
30
30
0
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
t
Chip Enable to End-of-Write
Address Valid to End-of-Write
Address Set-up Time
Write Pulse Width(4)
t
t
t
15
0
15
0
25
0
t
Write Recovery Time
Data Valid to End-of-Write
Output High-Z Time(1)
Data Hold Time
t
10
12
15
____
____
____
t
10
10
15
____
____
____
t
0
0
0
____
____
____
t
Write Enable to Output in High-Z(1)
Output Active from End-of-Write(1)
10
10
15
____
____
____
t
0
0
0
ns
2692 tbl 09
7132X55
7132X100
7142X55
Com'l &
Military
7142X100
Com'l &
Military
Symbol
Parameter
Min.
Max.
Min.
Max.
Unit
WRITE CYCLE
____
____
____
____
____
____
____
____
____
____
____
____
____
____
t
WC
EW
AW
AS
WP
WR
DW
HZ
DH
WZ
OW
Write Cycle Time(3)
55
40
40
0
100
90
90
0
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
t
Chip Enable to End-of-Write
Address Valid to End-of-Write
Address Set-up Time
t
t
t
Write Pulse Width(4)
30
0
55
0
t
Write Recovery Time
t
Data Valid to End-of-Write
Output High-Z Time(1)
20
40
____
____
t
25
40
____
____
t
Data Hold Time
0
0
____
____
t
Write Enable to Output in High-Z(1)
Output Active from End-of-Write(1)
30
40
____
____
t
0
0
ns
2692 tbl 10
NOTES:
1. Transition is measured 0mV from Low or High-impedance voltage with Output Test Load (Figure 2). This parameter is guaranteed by device characterization
but is not production tested.
2. PLCC package only.
3. For Master/Slave combination, tWC = tBAA + tWP, since R/W = VIL must occur after tBAA.
4. If OE is LOW during a R/W controlled write cycle, the write pulse width must be the larger of tWP or (tWZ + tDW) to allow the I/O drivers to turn off data to be placed on the
bus for the required tDW. If OE is High during a R/W controlled write cycle, this requirement does not apply and the write pulse can be as short as the specified tWP.
5. 'X' in part numbers indicates power rating (SA or LA).
6. Industrial temperature: for specific speeds, packages and powers contact your sales office.
9
6.42