IDT7027S/L
High-Speed 32K x 16 Dual-Port Static RAM
Military, Industrial and Commercial Temperature Ranges
DC Electrical Characteristics Over the Operating
Temperature and Supply Voltage Range(1,6,7) (VCC = 5.0V ± 10%)
7027X20
Com'l Only
7027X25
Com'l, Ind
& Military
7027X35
Com'l &
Military
7027X55
Com'l &
Military
Symbol
Parameter
Test Condition
Version
COM'L
Typ.(2) Max. Typ.(2) Max. Typ.(2) Max. Typ.(2) Max. Unit
ICC
Dynamic Operating
Current
(Both Ports Active)
S
L
185
185
325
285
180
170
305
265
160
160
295
255
150
150
270
230
mA
mA
mA
CE = VIL, Outputs Disabled
SEM = VIH
(3)
f = fMAX
____
____
____
____
MIL &
IND
S
L
170
170
345
305
160
160
335
295
150
150
310
270
ISB1
ISB2
Standby Current
(Both Ports - TTL Level
Inputs)
COM'L
S
L
55
55
90
70
40
40
85
60
30
30
85
60
20
20
85
60
CEL = CER = VIH
SEMR = SEML = VIH
(3)
f = fMAX
____
____
____
____
MIL &
IND
S
L
40
40
100
80
30
30
100
80
20
20
100
80
(5)
Standby Current
(One Port - TTL Level
Inputs)
COM'L
S
L
120
120
215
185
105
105
200
170
95
95
185
155
85
85
165
135
CE"A" = VIL and CE"B" = VIH
Active Port Outputs Disabled,
(3)
f=fMAX
____
____
____
____
MIL &
IND
S
L
105
105
230
200
95
95
215
185
85
85
195
165
SEMR = SEML = VIH
ISB3
ISB4
Full Standby Current
Both Ports CEL and
COM'L
S
L
1.0
0.2
15
5
1.0
0.2
15
5
1.0
0.2
15
5
1.0
0.2
15
5
mA
mA
(Both Ports - All CMOS CER > VCC - 0.2V
Level Inputs)
VIN > VCC - 0.2V or
____
____
____
____
VIN < 0.2V, f = 0(4)
MIL &
IND
S
L
1.0
0.2
30
10
1.0
0.2
30
10
1.0
0.2
30
10
SEMR = SEML > VCC - 0.2V
Full Standby Current
(One Port - All CMOS
Level Inputs)
CE"A" < 0.2V and
COM'L
S
L
115
115
190
160
100
100
170
145
90
90
160
135
80
80
135
110
(5)
CE"B" > VCC - 0.2V
SEMR = SEML > VCC - 0.2V
VIN > VCC - 0.2V or
____
____
____
____
MIL &
IND
S
L
100
100
200
175
90
90
190
165
80
80
175
150
VIN < 0.2V, Active Port Outputs
(3)
Disable d, f = fMAX
3199 tbl 10
NOTES:
1. 'X' in part numbers indicates power rating (S or L).
2. VCC = 5V, TA = +25°C, and are not production tested. ICCDC = 120mA (Typ.)
3. At f = fMAX, address and control lines (except Output Enable) are cycling at the maximum frequency read cycle of 1/ tRC, and using “AC Test Conditions” of input
levels of GND to 3V.
4. f = 0 means no address or control lines change.
5. Port "A" may be either left or right port. Port "B" is the opposite from port "A".
6. Refer to Chip Enable Truth Table.
7. Industrial temperature: for other speeds, packages and powers contact your sales office.
6
6.42