ICS1894-40
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE
PHYCEIVER
10Base-T: Jabber Timing
The table below lists the significant time periods for the 10Base-T jabber. The time periods consist of timings of
signals on the following pins:
• TXEN
• TP_TX (that is, TP_TXP and TP_TXN)
• COL
The 10Base-T Jabber Timing Diagram shows the timing diagram for the time periods.
Note: For more information on 10Base-T jabber operations, see the section, “10Base-T Operation: Jabber”.
Time
Parameter
Conditions
Min. Typ. Max. Units
Period
t1
t2
Jabber Activation Time
10Base-T Half Duplex
10Base-T Half Duplex
20
–
–
35
ms
ms
Jabber De-Activation Time
300
325
10Base-T Jabber Timing Diagram
TXEN
t1
TP_TX
COL
t2
IDT® 10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE
48
ICS1894-40
REV G 060110