IS61C512
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
VCC
5V ± 10%
5V ± 10%
0°C to +70°C
–40°C to +85°C
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter
Test Conditions
VCC = Min., IOH = –4.0 mA
Min.
2.4
—
Max.
—
Unit
V
VOH
VOL
VIH
VIL
ILI
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage(1)
Input Leakage
VCC = Min., IOL = 8.0 mA
0.4
V
2.2
–0.3
–2
VCC + 0.5
V
0.8
2
V
GND ≤ VIN ≤ VCC
µA
µA
ILO
Output Leakage
GND ≤ VOUT ≤ VCC, Outputs Disabled
–2
2
Notes:
1. VIL = –3.0V for pulse width less than 10 ns.
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
-15 ns
-20 ns
Min. Max.
-25 ns
-35 ns
Symbol Parameter
Test Conditions
Min. Max.
Min. Max.
Min. Max.
Unit
ICC1
ICC2
ISB1
Vcc Operating
Supply Current
VCC = Max.,
Com.
Ind.
—
—
70
—
—
—
70
90
—
—
70
90
—
—
70
90
mA
IOUT = 0 mA, f = 0
Vcc Dynamic Operating
Supply Current
VCC = Max.,
IOUT = 0 mA, f = fMAX
Com.
Ind.
—
—
125
—
—
—
115
135
—
—
105
125
—
—
90
115
mA
mA
TTL Standby Current
(TTL Inputs)
VCC = Max.,
VIN = VIH or VIL
Com.
Ind.
—
—
25
—
—
—
25
30
—
—
25
30
—
—
25
30
CE1
CE2
≥
≤
VIH or
VIL, f = 0
ISB2
CMOS Standby
Current (CMOS Inputs)
VCC = Max.,
Com.
Ind.
—
—
750
—
—
—
750
1
—
—
750
1
—
—
750
1
µA
mA
CE1
≥
≤
VCC – 0.2V,
0.2V,
CE2
VIN
VIN
≥
VCC – 0.2V, or
0.2V, f = 0
≤
Notes:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE(1,2)
Symbol
CIN
Parameter
Input Capacitance
Conditions
VIN = 0V
Max.
5
Unit
pF
COUT
Output Capacitance
VOUT = 0V
7
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: TA = 25°C, f = 1 MHz, Vcc = 5.0V.
Integrated Circuit Solution Inc.
3
SR011-0B