IC61LV5128
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
VCC
3.3V ± 10%
3.3V ± 10%
0°C to +70°C
–40°C to +85°C
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter
Test Conditions
VCC = Min., IOH = –4.0 mA
Min.
2.4
Max.
—
Unit
V
VOH
VOL
VIH
VIL
ILI
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage(1)
Input Leakage
VCC = Min., IOL = 8.0 mA
—
0.4
V
2.0
VCC + 0.3
0.8
V
–0.3
V
GND ≤ VIN ≤ VCC
Com.
Ind.
–1
–5
1
5
µA
ILO
Output Leakage
GND ≤ VOUT ≤ VCC, Outputs Disabled Com.
–1
–5
1
5
µA
Ind.
Notes:
1. VIL = –3.0V for pulse width less than 10 ns.
2. The Vcc operating range for 8 ns is 3.3V +10%, -5%.
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
-8 ns
Min. Max.
-10 ns
Min. Max.
-12 ns
Min. Max.
-15 ns
Min. Max. Unit
Symbol
Parameter
TestConditions
ICC
Vcc Dynamic Operating
Supply Current
VCC = Max.,
IOUT = 0 mA, f = fMAX
Com.
Ind.
—
—
300
310
—
—
280
290
—
—
260
270
—
—
240
250
mA
ISB1
ISB2
TTL Standby Current
(TTL Inputs)
VCC = Max.,
VIN = VIH or VIL
Com.
Ind.
—
—
55
65
—
—
55
65
—
—
55
65
—
—
55
65
mA
CE
≥ VIH , f = 0
CMOS Standby
Current (CMOS Inputs)
VCC = Max.,
Com.
Ind.
—
—
10
15
—
—
10
15
—
—
10
15
—
—
10
15
mA
CE
VIN
VIN
≥
≥
≤
VCC – 0.2V,
VCC – 0.2V, or
0.2V, f = 0
Note:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE(1,2)
Symbol
CIN
Parameter
Input Capacitance
Conditions
VIN = 0V
Max.
6
Unit
pF
COUT
Output Capacitance
VOUT = 0V
8
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: TA = 25°C, f = 1 MHz, Vcc = 3.3V.
4
Integrated Circuit Solution, Inc.
AHSR021-0A 09/11/2001