HY29F002T
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
Read Status Data (last two cycles)
tW C
tAS
tAH
Addresses
CE#
0x555
PA
PA
PA
tG H W L
OE#
tCH
tW P
WE#
tCS
tW P H
tW H W H 1
Data
0xA0
PD
Status
DOUT
tDS
tDH
VCC
tVCS
Notes:
1. PA = Program Address, PD = Program Data, DOUT is the true data at the program address.
2. VCC shown only to illustrate tVCS measurement references. It cannot occur as shown during a valid command sequence.
Figure 15. Program Operation Timings
Rev. 4.1/May 01
26