RFM70 V1.0
11
12
13
14
15
RX_PW_P0
Reserved
7:6
5:0
00
R/W
R/W
Only '00' allowed
Number of bytes in RX payload in data pipe
0 (1 to 32 bytes).
0: not used
1 = 1 byte
…
RX_PW_P0
000000
32 = 32 bytes
RX_PW_P1
Reserved
7:6
5:0
00
R/W
R/W
Only '00' allowed
Number of bytes in RX payload in data pipe
1 (1 to 32 bytes).
0: not used
1 = 1 byte
…
RX_PW_P1
000000
32 = 32 bytes
RX_PW_P2
Reserved
7:6
5:0
00
R/W
R/W
Only '00' allowed
Number of bytes in RX payload in data pipe
RX_PW_P2
2 (1 to 32 bytes).
0: not used
1 = 1 byte
…
000000
32 = 32 bytes
RX_PW_P3
Reserved
7:6
5:0
00
R/W
R/W
Only '00' allowed
Number of bytes in RX payload in data pipe
000000
3 (1 to 32 bytes).
0: not used
1 = 1 byte
…
RX_PW_P3
32 = 32 bytes
RX_PW_P4
Reserved
7:6
5:0
00
R/W
R/W
Only '00' allowed
Number of bytes in RX payload in data pipe
4 (1 to 32 bytes).
0: not used
1 = 1 byte
…
RX_PW_P4
000000
32 = 32 bytes
16
RX_PW_P5
Reserved
7:6
5:0
00
R/W
R/W
Only '00' allowed
Number of bytes in RX payload in data pipe
RX_PW_P5
000000
5 (1 to 32 bytes).
0: not used
1 = 1 byte
…
32 = 32 bytes
17
FIFO_STATUS
Reserved
TX_REUSE
FIFO Status Register
Only '0' allowed
Reuse last transmitted data packet if set
high.
7
6
0
0
R/W
R
Tel: +86‐755‐86096587 Fax: +86‐755‐86096602 E‐mail: sales@hoperf.com http://www.hoperf.com
18