3.3V Uniform Sector
Dual and Quad Serial Flash
GD25Q80C
Figure 24. Release Power-Down/Read Device ID Sequence Diagram
CS#
0
1
2
3
4
5
6
7
8
9
29 30 31 32 33 34 35 36 37 38
SCLK
tRES2
Command
ABH
3 Dummy Bytes
23 22
MSB
SI
2
1
0
Device ID
SO
High-Z
7
6
5
4
3
2
1
0
MSB
Deep Power-down Mode Stand-by Mode
7.22. Read Manufacture ID/ Device ID (REMS) (90H)
The Read Manufacturer/Device ID command is an alternative to the Release from Power-Down / Device ID command
that provides both the JEDEC assigned Manufacturer ID and the specific Device ID.
The command is initiated by driving the CS# pin low and shifting the command code “90H” followed by a 24-bit address
(A23-A0) of 000000H. After which, the Manufacturer ID and the Device ID are shifted out on the falling edge of SCLK with
most significant bit (MSB) first as shown in Figure28. If the 24-bit address is initially set to 000001H, the Device ID will be
read first.
Figure 25. Read Manufacture ID/ Device ID Sequence Diagram
CS#
0
1
2
3
4
5
6
7
8
9 10
28 29 30 31
SCLK
Command
24-bit address
23 22 21
SI
90H
3
2
1
0
High-Z
SO
CS#
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
SCLK
SI
Device ID
Manufacturer ID
SO
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
MSB
MSB
30