GS9060 Data Sheet
Table 3-12: Host Interface Description for EDH Calculation Range Registers
Register Name
Bit
Name
Description
R/W
Default
AP_LINE_START_F0
Address: 12h
15-10
9-0
Not Used
AP_LINE_START_F0[9:0]
Field 0 Active Picture start line data used to set
EDH calculation range outside of SMPTE RP
165 values.
R/W
0
AP_LINE_END_F0
Address: 13h
15-10
9-0
Not Used
AP_LINE_END_F0[9:0]
Field 0 Active Picture end line data used to set
EDH calculation range outside of SMPTE RP
165 values.
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0
0
0
0
0
0
0
AP_LINE_START_F1
Address: 14h
15-10
9-0
Not Used
AP_LINE_START_F1[9:0]
Field 1 Active Picture end line data used to set
EDH calculation range outside of SMPTE RP
165 values.
AP_LINE_END_F1
Address: 15h
15-10
9-0
Not Used
AP_LINE_END_F1[9:0]
Field 1 Active Picture end line data used to set
EDH calculation range outside of SMPTE RP
165 values.
FF_LINE_START_F0
Address: 16h
15-10
9-0
Not Used
FF_LINE_START_F0[9:0]
Field 0 Full Field start line data used to set EDH
calculation range outside of SMPTE RP 165
values.
FF_LINE_END_F0
Address: 17h
15-10
9-0
Not Used
FF_LINE_END_F0[9:0]
Field 0 Full Field start line data used to set
EDH calculation range outside of SMPTE RP
165 values.
FF_LINE_START_F1
Address: 18h
15-10
9-0
Not Used
FF_LINE_START_F1[9:0]
Field 1 Full Field start line data used to set EDH
calculation range outside of SMPTE RP 165
values.
FF_LINE_END_F1
Address: 19h
15-10
9-0
Not Used
FF_LINE_END_F1[9:0]
Field 1 Full Field end line data used to set EDH
calculation range outside of SMPTE RP 165
values.
3.10.5.3 Lock Error Detection
The LOCKED pin of the GS9060 indicates the lock status of the reclocker and lock
detect blocks of the device. Only when the LOCKED pin is asserted HIGH has the
device correctly locked to the received data stream, Section 3.6 on page 28.
The GS9060 will also indicate lock error to the host interface when LOCKED =
LOW by setting the LOCK_ERR bit in the ERROR_STATUS register HIGH.
22208 - 8 January 2007
45 of 61