GS9060 Data Sheet  
Table 3-12: Host Interface Description for EDH Calculation Range Registers  
Register Name  
Bit  
Name  
Description  
R/W  
Default  
AP_LINE_START_F0  
Address: 12h  
15-10  
9-0  
Not Used  
AP_LINE_START_F0[9:0]  
Field 0 Active Picture start line data used to set  
EDH calculation range outside of SMPTE RP  
165 values.  
R/W  
0
AP_LINE_END_F0  
Address: 13h  
15-10  
9-0  
Not Used  
AP_LINE_END_F0[9:0]  
Field 0 Active Picture end line data used to set  
EDH calculation range outside of SMPTE RP  
165 values.  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
0
0
0
0
0
0
0
AP_LINE_START_F1  
Address: 14h  
15-10  
9-0  
Not Used  
AP_LINE_START_F1[9:0]  
Field 1 Active Picture end line data used to set  
EDH calculation range outside of SMPTE RP  
165 values.  
AP_LINE_END_F1  
Address: 15h  
15-10  
9-0  
Not Used  
AP_LINE_END_F1[9:0]  
Field 1 Active Picture end line data used to set  
EDH calculation range outside of SMPTE RP  
165 values.  
FF_LINE_START_F0  
Address: 16h  
15-10  
9-0  
Not Used  
FF_LINE_START_F0[9:0]  
Field 0 Full Field start line data used to set EDH  
calculation range outside of SMPTE RP 165  
values.  
FF_LINE_END_F0  
Address: 17h  
15-10  
9-0  
Not Used  
FF_LINE_END_F0[9:0]  
Field 0 Full Field start line data used to set  
EDH calculation range outside of SMPTE RP  
165 values.  
FF_LINE_START_F1  
Address: 18h  
15-10  
9-0  
Not Used  
FF_LINE_START_F1[9:0]  
Field 1 Full Field start line data used to set EDH  
calculation range outside of SMPTE RP 165  
values.  
FF_LINE_END_F1  
Address: 19h  
15-10  
9-0  
Not Used  
FF_LINE_END_F1[9:0]  
Field 1 Full Field end line data used to set EDH  
calculation range outside of SMPTE RP 165  
values.  
3.10.5.3 Lock Error Detection  
The LOCKED pin of the GS9060 indicates the lock status of the reclocker and lock  
detect blocks of the device. Only when the LOCKED pin is asserted HIGH has the  
device correctly locked to the received data stream, Section 3.6 on page 28.  
The GS9060 will also indicate lock error to the host interface when LOCKED =  
LOW by setting the LOCK_ERR bit in the ERROR_STATUS register HIGH.  