Peripheral operating requirements and behaviors
6.8.8 I2S/SAI Switching Specifications
This section provides the AC timing for the I2S/SAI module in master mode (clocks are
driven) and slave mode (clocks are input). All timing is given for noninverted serial clock
polarity (TCR2[BCP] is 0, RCR2[BCP] is 0) and a noninverted frame sync (TCR4[FSP]
is 0, RCR4[FSP] is 0). If the polarity of the clock and/or the frame sync have been
inverted, all the timing remains valid by inverting the bit clock signal (BCLK) and/or the
frame sync (FS) signal shown in the following figures.
6.8.8.1 Normal Run, Wait and Stop mode performance over the full
operating voltage range
This section provides the operating performance over the full operating voltage for the
device in Normal Run, Wait and Stop modes.
Table 36. I2S/SAI master mode timing
Num.
Characteristic
Min.
Max.
Unit
Operating voltage
1.71
40
3.6
—
V
S1
S2
S3
S4
S5
I2S_MCLK cycle time
ns
I2S_MCLK pulse width high/low
45%
80
55%
—
MCLK period
I2S_TX_BCLK/I2S_RX_BCLK cycle time (output)
I2S_TX_BCLK/I2S_RX_BCLK pulse width high/low
ns
45%
—
55%
15
BCLK period
ns
I2S_TX_BCLK/I2S_RX_BCLK to I2S_TX_FS/
I2S_RX_FS output valid
S6
I2S_TX_BCLK/I2S_RX_BCLK to I2S_TX_FS/
I2S_RX_FS output invalid
0
—
ns
S7
S8
S9
I2S_TX_BCLK to I2S_TXD valid
I2S_TX_BCLK to I2S_TXD invalid
—
0
15
—
—
ns
ns
ns
I2S_RXD/I2S_RX_FS input setup before
I2S_RX_BCLK
25
S10
I2S_RXD/I2S_RX_FS input hold after I2S_RX_BCLK
0
—
ns
K20 Sub-Family Data Sheet, Rev. 4 5/2012.