ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 2. Maximum Ratings (continued)
All voltages are with respect to ground unless otherwise noted.
Ratings
Symbol
Value
Unit
Notes
1. Exceeding these limits may cause malfunction or permanent damage to the device.
2. ESD data available upon request.
3. ESD testing is performed in accordance with the Human Body Model (HBM) (AEC-Q100-002), the Machine Model (MM) (AEC-Q100-
003), and the Charge Device Model (CDM), Robotic (AEC-Q100-011).
STATIC ELECTRICAL CHARACTERISTICS
Table 3. Static Electrical Characteristics
Characteristics noted under conditions of 3.0 V ≤ VDD ≤ 5.5 V, 6.0 V ≤ VPWR ≤ 32 V, -40°C ≤ TC ≤ 125°C, and calibrated
timers, unless otherwise noted. Where typical values reflect the parameter’s approx. average value with VPWR = 13 V, TA =
25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUT (VDD, VPWR)
Supply Voltage(4)
Fully Operational
Full Parameter Specification
V
4.5
6.0
–
36
32
V
(
)
PWR FO
Supply Current
I
mA
VPWR(ON)
All Outputs Disabled (Normal Mode)
–
10.0
14.0
Sleep State Supply Current (Must have V
VPWR = 32 V
≤ 0.8 V for sleep state),
I
μA
DD
VPWR(SS)
–
15
39
1.5
4.0
200
–
30
42
V
V
V
V
V
Over-voltage Shutdown Threshold Voltage(5)
VPWR(OV)
36.5
0.5
3.0
100
5.3
3.0
V
V
PWR
PWR
PWR
PWR
PWR
Over-voltage Shutdown Hysteresis Voltage
V
3.0
4.4
300
8.99
5.5
PWR(OV-HYS)
VPWR(UV)
Under-voltage Shutdown Threshold Voltage(6)
Under-voltage Shutdown Hysteresis Voltage
Low Operating Voltage (Low-voltage reported via the SPI)(7)
V
VPWR(UV-HYS)
VPWR(LOV)
mV
V
VDD Supply Voltage
V
–
V
DD
VDD Supply Current
I
mA
VDD
Static Condition and does not include VDD current out of device
–
–
1.0
2.8
VDD Supply Under-voltage (Sleep State) Threshold Voltage(8)
INJECTOR DRIVER OUTPUTS (OUT 0:3)
Drain-to-Source ON Resistance
V
0.8
2.5
V
DD(UV)
R
Ω
DS(ON)
–
–
–
–
0.2
–
0.3
–
I
I
I
= 1.0 A, T = 125°C, VPWR = 13 V
OUT
OUT
OUT
J
= 1.0 A, T = 25°C, VPWR = 13 V
J
= 1.0 A, T = -40°C, VPWR = 13 V
–
J
Output Self Limiting Current
I
3.0
–
6.0
A
V
OUT(LIM)
Output Fault Detection Voltage Threshold(9)
Outputs Programmed OFF (Open Load)
Outputs Programmed ON (Short to Battery)
V
OUT(FLT-TH)
2.0
2.5
3.0
Output OFF Open Load Detection Current
I
μA
(OFF)OCO
V
V
= 18 V, Outputs Programmed OFF
40
20
75
115
115
DRAIN
DRAIN
= 32 V, Outputs Programmed OFF (-40°C)
Output ON Open Load Detection Current
I
mA
(ON)OCO
Current less then specification value considered open
100
200
33810
Analog Integrated Circuit Device Data
Freescale Semiconductor
6