FUNCTIONAL DEVICE OPERATIONS  
LOGIC COMMANDS AND REGISTERS  
LIN Control Register - LINCR  
LIN Status Register - LINSR  
This register controls the LIN physical interface block.  
Writing the LIN Control Register (LINCR) returns the LIN  
Status Register (LINSR).  
This register returns the status of the LIN physical  
interface block and is also returned when writing to the  
LINCR.  
Table 14. LIN Control Register - $4  
Table 16. LIN Status Register - $4/$5  
C3  
C2  
C1  
C0  
S3  
S2  
S1  
S0  
Write  
LDVS  
RXONLY  
LSR1  
LSR0  
Read  
RXSHORT  
TXDOM  
LINOT  
LINOC  
Reset  
Value  
0
0
0
0
RXSHORT - RXD Pin Short-Circuit  
POR, Reset  
Mode, ext_reset  
or LIN failure  
gone*  
POR, Reset  
Mode or  
ext_reset  
This read-only bit indicates a short-circuit condition on the  
RXD pin (shorted either to 5.0V or to Ground). The short-  
circuit delay must be a worst case of 8µs to be detected and  
to shut down the driver. To clear this bit, it must be read after  
the condition is gone (transition detected on RXD pin). The  
LIN driver is automatically re-enabled once the condition is  
gone.  
Reset  
Condition  
POR  
* LIN failure gone: if LIN failure (overtemp, TXD/RXD short) was set, the flag  
resets automatically when the failure is gone.  
LDVS - LIN Dominant Voltage Select  
1 = RXD short-circuit condition.  
0 = None.  
This write-only bit controls the LIN Dominant voltage:  
1 = LIN Dominant Voltage = VLIN_DOM_1 (1.7V typ)  
0 = LIN Dominant Voltage = VLIN_DOM_0 (1.1V typ)  
TXDOM - TXD Permanent Dominant  
This read-only bit signals the detection of a TXD pin stuck  
at dominant (Ground) condition and the resultant shutdown in  
the LIN transmitter. This condition is detected after the TXD  
pin remains in dominant state for more than 1 second (typical  
value).  
RXONLY - LIN Receiver Operation Only  
This write-only bit controls the behavior of the LIN  
transmitter.  
In Normal Mode, the activation of the RXONLY bit disables  
the LIN transmitter. In case of a LIN error condition, this bit is  
automatically set.  
To clear this bit, it must be read after TXD has gone high.  
The LIN driver is automatically re-enabled once TXD goes  
High.  
In Stop Mode this bit disables the LIN wake-up  
functionality, and the RXD pin will reflect the state of the LIN  
bus.  
1 = TXD stuck at dominant fault detected.  
0 = None.  
1 = only LIN receiver active (Normal Mode) or LIN wake-  
up disabled (Stop Mode).  
LINOT - LIN Driver Over-temperature Shutdown  
0 = LIN fully enabled.  
This read-only bit signals that the LIN transceiver was  
shutdown due to over-temperature. The transmitter is  
automatically re-enabled after the over-temperature  
condition is gone and TXD is high. The LINOT bit is cleared  
after SPI read once the condition is gone.  
LSRx - LIN Slew-Rate  
This write-only bit controls the LIN driver slew-rate in  
accordance with Table 15.  
1 = LIN over-temperature shutdown  
0 = None  
Table 15. LIN Slew-Rate Control  
LSR1  
LSR0  
Description  
LINOC - LIN Driver Over-Current Shutdown  
0
0
1
1
0
1
0
1
Normal Slew Rate (up to 20kb/s)  
Slow Slew Rate (up to 10kb/s)  
Fast Slew Rate (up to 100kb/s)  
Reserved  
This read-only bit signals an over-current condition  
occurred on the LIN pin. The LIN driver is not shut down but  
an IRQ is generated. To clear this bit, it must be read after the  
condition is gone.  
1 = LIN over-current shutdown  
0 = None  