MC33910BAC / MC34910BAC
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 33. Static Electrical Characteristics (continued)
Characteristics noted under conditions 5.5 V ≤ VSUP ≤ 18 V, -40°C ≤ TA ≤ 125°C for the 33910 and -40°C ≤ TA ≤ 85°C for the
34910, unless otherwise noted. Typical values noted reflect the approximate parameter mean at TA = 25°C under nominal
conditions, unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
HIGH SIDE OUTPUT HS1 AND HS2 PINS (HS1, HS2)
Output Drain-to-Source On Resistance
TJ = 25°C, ILOAD = 50 mA; VSUP > 9.0 V
RDS(ON)
Ω
–
–
–
–
–
–
7.0
10
14
TJ = 150°C, ILOAD = 50 mA; VSUP > 9.0 V(94)
TJ = 150°C, ILOAD = 30 mA; 5.5 V < VSUP < 9.0 V(94)
Output Current Limitation(95)
0 V < VOUT < VSUP - 2.0 V
ILIMHS1
mA
60
120
250
Open Load Current Detection(96)
IOLHSx
ILEAK
–
–
5.0
–
7.5
10
mA
µA
V
Leakage Current (-0.2 V < VHSx < VS2 + 0.2 V)
Short Circuit Detection Threshold(97)
5.5 V < VSUP < 27 V
VTHSC
VSUP - 2
–
–
Over-temperature Shutdown(98), (99)
Over-temperature Shutdown Hysteresis(99)
L1 INPUT PIN (L1)
THSSD
150
–
165
10
180
–
°C
°C
THSSD_HYS
Low Detection Threshold
5.5 V < VSUP < 27 V
VTHL
VTHH
VHYS
IIN
V
V
2.0
3.0
0.5
2.5
3.5
1.0
3.0
4.0
1.5
High Detection Threshold
5.5 V < VSUP < 27 V
Hysteresis
V
5.5 V < VSUP < 27 V
Input Current(100)
-0.2 V < VIN < VS1
µA
kΩ
-10
–
10
–
Analog Input Impedance(101)
RL1IN
800
1550
Analog Input Divider Ratio (RATIOL1 = VL1 / VADOUT0
L1DS (L1 Divider Select) = 0
)
RATIOL1
0.95
3.42
1.0
3.6
1.05
3.78
L1DS (L1 Divider Select) = 1
Analog Output Offset Ratio
L1DS (L1 Divider Select) = 0
L1DS (L1 Divider Select) = 1
VRATIOL1-
mV
%
OFFSET
-80
-22
0.0
0.0
80
22
Analog Inputs Matching
L1MATCHING
L1DS (L1 Divider Select) = 0
L1DS (L1 Divider Select) = 1
96
96
100
100
104
104
Notes
94. This parameter is production tested up to TA = 125°C and guaranteed by process monitoring up to TJ = 150°C.
95. When over-current occurs, the high side stays ON with limited current capability and the HS1CL flag is set in the HSSR.
96. When open-load occurs, the flag (HS1OP) is set in the HSSR.
97. When short circuit occurs and if HVSE flag is enabled, HS1 automatic shutdown.
98. When over-temperature shutdown occurs, both high sides are turned off. All flags in HSSR are set.
99. Guaranteed by characterization but, not production tested
100. Analog multiplexer input disconnected from L1 input pin.
101. Analog multiplexer input connected to L1 input pin.
33910
Analog Integrated Circuit Device Data
Freescale Semiconductor
56