FUNCTIONAL DEVICE OPERATION  
PROTECTION AND DIAGNOSTIC FEATURES  
resistance limiting the internal clamp current according to the  
specification.  
Table 5 summarizes the various methods for resetting the  
device from the latched Fail-safe Mode.  
The Watchdog timeout is a multiple of an internal oscillator  
and is specified in the Table 15, page 24. As long as the WD  
bit (D15) of an incoming SPI message is toggled within the  
minimum watchdog timeout period (WDTO), based on the  
programmed value of the WDR, the device will operate  
normally. If an internal watchdog timeout occurs before the  
WD bit, the device will revert to a Fail-safe mode until the  
device is reinitialized.  
If the FSI pin is tied to GND, the Watchdog fail-safe  
operation is disabled.  
LOSS OF V  
DD  
If the external 5.0 V supply is not within specification, or  
even disconnected, all register content is reset. The outputs  
can still be driven by the direct inputs IN0:IN3. The 33874  
uses the battery input to power the output MOSFET-related  
current sense circuitry and any other internal logic providing  
fail-safe device operation with no VDD supplied. In this state,  
During the Fail-safe Mode, the outputs will be ON or OFF  
depending upon the resistor RFS connected to the FSI pin,  
regardless of the state of the various direct inputs and modes  
(Table 6).  
the watchdog, under-voltage, over-voltage, over-temperature  
(latched) and over-current circuitry are fully operational with  
default values.  
Table 6. Output State During Fail-safe Mode  
RFS (kΩ)  
High Side State  
FAULT MODE  
0 (shorted to ground)  
Fail-safe Mode Disabled  
All HS OFF  
This 33874 indicates the faults below as they occur by  
driving the FS pin to logic [0]:  
6.0  
15  
• Over-temperature fault  
HS0 ON  
• Over-voltage and under-voltage fault  
• Open load fault  
• Over-current fault (high and low)  
HS1:HS3 OFF  
30 (open)  
HS0 and HS2 ON  
HS1 and HS3 OFF  
The FS pin will automatically return to logic [1] when the  
fault condition is removed, except for overcurrent,  
overtemperature (in case of latching configuration) and in  
some cases of undervoltage.  
In the Fail-safe Mode, the SPI register content is retained  
except for over-current high and low detection levels, timing  
and latched over-temperature which are reset to their default  
value (SOCL, SOCH, and OCTL and OT_latch_[0:3] bits).  
Then the watchdog, over-voltage, over-temperature, and  
over-current circuitry (with default value) are fully operational.  
The FS pin reports all faults. For latched faults, this pin is  
reset by a new Switch ON command (via the SPI or direct  
input IN).  
The Fail-safe Mode can be detected by monitoring the  
WDTO bit D2 of the WD register. This bit is logic [1] when the  
device is in Fail-safe Mode. The device can be brought out of  
the Fail-safe Mode by transitioning the WAKE and RST pins  
from logic [1] to logic [0] or forcing the FSI pin to logic [0].  
Fault information is retained in the fault register and is  
available (and reset) via the SO pin during the first valid SPI  
communication (refer to Table 17, page 26).  
PROTECTION AND DIAGNOSTIC FEATURES  
• in Fail-safe Mode: the FSI input must be grounded and  
then set to its nominal voltage to switch ON the outputs.  
OVER-TEMPERATURE FAULT (LATCHING OR  
NON-LATCHING)  
The over-temperature fault (one for each output) is  
reported by SPI. If the over-temperature is latched, the SPI  
reports OTF_s = [1] and OCLF_s = [1]. In case of non-  
latched, OTF_s = [1] only is reported.  
The 33874 incorporates over-temperature detection and  
shutdown circuitry for each output structure.  
The over-temperature is latched per default and can be  
unlatched through SPI with OT_latch_[0:3] bits.  
The fault bits will be cleared in the status register after either  
a valid SPI read command or a power on reset of the device.  
An over-temperature fault condition results in turning OFF  
the corresponding output. To remove the fault and be able to  
turn ON again the outputs, the failure must be removed and:  
• in Normal Mode: the corresponding output must be  
commanded OFF and ON again in case of over-  
OVERCURRENT FAULT (LATCHING)  
The 33874 has eight programmable over-current low  
detection levels (IOCL) and two programmable over-current  
temperature latched (OT_latch bit = 0).  
• in Normal Mode: the corresponding output turns ON  
automatically if the temperature is below TSD-TSD(HYS) in  
case of unlatched over-temperature (OT_latch bit = 1).  
high detection levels (IOCH) for maximum device protection.  
The two selectable, simultaneously active over-current  
33874  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  
19  