Table 6.4
SEG output
SEG0
SEG159
ADC “0”
0(H)→ Column Address →9F(H)
9F(H)← Column Address ←0(H)
(D0)
“1”
dynamic modification of the line address, screen scroll
and page change are enabled.
6.2.4 Line address circuit
The line address circuit specifies the line address
corresponding to COM output when the contents of the
display data RAM is displayed, as shown in Fig. 6.5 and
6.6. Normally, the top line of the display (COM0 output
in the case of normal rotation of the common output
status and COM131 output in the case of reverse rotation)
is specified by the Display Start Line Address Set
command. The display area starts from the specified
display start line address to cover the area corresponding
to the lines specified by the DUTY Set command in the
direction where the line address increments.
6.2.5 Area scroll
The display area can be divided into the display area
fixed in the COM direction and scrollable area by the
area scroll command. The scroll area is set by a scroll
mode, scroll start line address (AS), scroll end address
(AE), and scroll display line count (AL) as parameters
for the area scroll command. Display start line address
(DL) in the scroll area can be specified by the display
start line address set command.
If the display start line address set command is used for
Fixed area
Scrollable
Fixed area
Scrollable
Scrollable
Scrollable
Fixed area
Fixed area
Mode 3
Mode 0
Mode 1
Mode 2
Scroll mode
00H
Upper fixed area
Number of line : AS
AS-1
DL
Scroll area
Number of line : AL
AE+1
Lower fixed area
Number of line
Final line address
middle of reading the scroll area, the line address to be
read next will be 00H. When all the AL lines have been
read, the address to be read next will be AE + 1. When
reading is completed up to the final line address, the
control goes back to the line address DL, and parameter
AS is disabled. DL can be specified in the range from
00H to AE.
6.2.5.1 Mode 0 (full screen scroll)
This mode releases the area scroll. Parameters AS, AE
and AL are disabled,
6.2.5.2 Mode 1 (Upper scroll )
Reading starts from the line address DL to read AL lines
as a scroll area. If the line address AE is read in the
Rev. 2.1
EPSON
15