欢迎访问ic37.com |
会员登录 免费注册
发布采购

S1D15E06D03E000 参数 Datasheet PDF下载

S1D15E06D03E000图片预览
型号: S1D15E06D03E000
PDF下载: 下载PDF文件 查看货源
内容描述: 直接RAM的数据显示由显示数据RAM [Direct RAM data display by display data RAM]
分类和应用:
文件页数/大小: 74 页 / 668 K
品牌: EPSON [ EPSON COMPANY ]
 浏览型号S1D15E06D03E000的Datasheet PDF文件第15页浏览型号S1D15E06D03E000的Datasheet PDF文件第16页浏览型号S1D15E06D03E000的Datasheet PDF文件第17页浏览型号S1D15E06D03E000的Datasheet PDF文件第18页浏览型号S1D15E06D03E000的Datasheet PDF文件第20页浏览型号S1D15E06D03E000的Datasheet PDF文件第21页浏览型号S1D15E06D03E000的Datasheet PDF文件第22页浏览型号S1D15E06D03E000的Datasheet PDF文件第23页  
S1D15E06 Series  
6.2.5.3 Mode 2 (lower scroll)  
6.2.6 Display data latch circuit  
Reading starts from line address 00H to reach the line  
address AS-1 in the continuous reading mode. Upon  
completion of reading of line address AS-1, the line  
address moves to the DL to read the area corresponding  
to AL lines from the line address DL as a scroll area. If  
the final line address is read in the middle of reading the  
scroll area, the line address to be read next will be AS.  
When all AL lines have been read, the control goes back  
to the line address 00H, and parameter AE is disabled.  
DL can be specified in the range from AS to the final line  
address.  
The display data latch circuit is a latch to temporarily  
latch the display data output from then display data  
RAM to the liquid crystal drive circuit. Display normal/  
reverse, display ON/OFF, and display all lighting ON/  
OFF commands control the data in this latch, without  
the data in the display data RAM being controlled.  
6.2.7 Partial display  
Partial display of the screen is provided by the partial  
display ON/OFF command. The partial area (display  
start line, number of display lines) are set by the partial  
display set command.  
The display start line of the parameter shows the line  
assigned in the COM direction of the liquid crystal  
screen. It is different from the line address given in Fig.  
6.5 and 6.6.  
6.2.5.4 Mode 3 (Center scroll)  
Reading starts from line address 00H to reach the line  
address AS-1 in the continuous reading mode.  
Upon completion of reading of line address AS-1, the  
line address moves to the DL to read the area  
corresponding to AL lines from the line address DL as  
a scroll area. If the final line address is read in the  
middle of reading the scroll area, the line address to be  
read next will be AS. When all AL lines have been read,  
the line address will be AE+1. When up to the final line  
address has been read, the control goes back to the line  
address 00H, DL can be specified in the range from AS  
to AE.  
Example: When the point is set at 1 (COM4 to 7) by the  
Duty Reset command, the display line is  
assigned as shown below. If the display start  
line 4 and display line count 3 are specified  
by the partial display set command, the display  
area is COM8 to COM10.  
Display line  
LCD panel  
0
1
2
3
4
COM4  
COM5  
COM6  
COM7  
COM8  
COM9  
COM10  
COM11  
COM12  
COM13  
COM14  
5
6
7
8
9
10  
16  
EPSON  
Rev. 2.1  
 复制成功!