EN29LV400A
Flowchart 7a. In-System Sector Protect Flowchart
START
PLSCNT = 1
RESET# = VID
Wait 1 µs
No
First Write
Cycle =
60h?
Temporary Sector
Unprotect Mode
Yes
Set up sector
address
Sector Protect: Write 60h
to sector addr with
A6 = 0, A1 = 1, A0 = 0
Wait 150 µs
Verify Sector Protect:
Write 40h to sector
address with
A6 = 0, A1 = 1, A0 = 0
Increment
PLSCNT
Reset
PLSCNT = 1
Wait 0.4 µs
Read from sector
address with
A6 = 0, A1 = 1, A0
No
No
Data = 01h?
Yes
PLSCNT = 25?
Yes
Device failed
Yes
Protect another
sector?
No
Remove VID
from RESET#
Write reset
command
Sector Protect
Algorithm
Sector Protect
complete
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
©2005 Eon Silicon Solution, Inc., www.essi.com.tw
21