SL811HS  
Endpoint Control Registers  
Endpoint n Control Register [Address a = (EP# * 10h), b = (EP# * 10h)+8]. Each endpoint set has a Control register defined as  
follows:  
Table 22. Endpoint Control Register [Address EP0a/b:00h/08h, EP1a/b:10h/18h, EP2a/b:20h/28h, EP3a/b:30h/38h]  
7
6
5
4
3
2
1
0
Reserved  
Sequence  
Send STALL  
ISO  
Next Data Set  
Direction  
Enable  
Arm  
Bit Position Bit Name  
Function  
7
6
5
4
3
2
1
Reserved  
Sequence  
Send STALL  
ISO  
Sequence bit. '0' if DATA0, '1' if DATA1.  
When set to ‘1’, sends Stall in response to next request on this endpoint.  
When set to '1', allows Isochronous mode for this endpoint.  
'0' if next data set is ‘A’, '1' if next data set is 'B'.  
Next Data Set  
Direction  
Enable  
When Direction = '1', transmit to Host (IN). When Direction = '0', receive from Host (OUT).  
When Enable = '1', allows transfers for this endpoint. When set to ‘0’, USB transactions are  
ignored. If Enable = '1' and Arm = '0', the endpoint returns NAKs to USB transmissions.  
0
Arm  
Allows enabled transfers when set =’1’. Clears to '0' when transfer is complete.  
Endpoint Base Address [Address a = (EP# * 10h)+1, b = (EP# * 10h)+9]]. Pointer to memory buffer location for USB reads and  
writes.  
Table 23. Endpoint Base Address Reg [Address; EP0a/b:01h/09h, EP1a/b:11h/19h, EP2a/b:21h/29h, EP3a/b:31h/39h]  
7
6
5
4
3
2
1
0
EPxADD7  
EPxADD6  
EPxADD5  
EPxADD4  
EPxADD3  
EPxADD2  
EPxADD1  
EPxADD0  
Endpoint Base Length [Address a = (EP# * 10h)+2, b = (EP# * 10h)+A]. The Endpoint Base Length is the maximum packet size  
for IN/OUT transfers with the host. Essentially, this designates the largest packet size that is received by the SL811HS with an OUT  
transfer, or it designates the size of the data packet sent to the host for IN transfers.  
Table 24. Endpoint Base Length Reg [Address EP0a/b:02h/0Ah, EP1a/b:12h/1Ah, EP2a/b:22h/2Ah, EP3a/b:32h/3Ah]  
7
6
5
4
3
2
1
0
EPxLEN7  
EPxLEN6  
EPxLEN5  
EPxLEN4  
EPxLEN3  
EPxLEN2  
EPxLEN1  
EPxLEN0  
Document 38-08008 Rev. *F  