 浏览型号CY8C24223-SPPVC的Datasheet PDF文件第21页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第22页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第23页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第24页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第26页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第27页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第28页浏览型号CY8C24223-SPPVC的Datasheet PDF文件第29页  
CY8C24x23 Final Data Sheet  
3. Electrical Specifications  
3.3.9  
DC Programming Specifications  
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V  
and -40°C T 85°C, or 3.0V to 3.6V and -40°C T 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and  
A
A
are for design guidance only or unless otherwise specified.  
Table 3-15. DC Programming Specifications  
Symbol  
Description  
Min  
Typ  
Max  
Units  
mA  
Notes  
I
Supply Current During Programming or Verify  
5
25  
0.8  
DDP  
V
V
Input Low Voltage During Programming or Verify  
Input High Voltage During Programming or Verify  
V
ILP  
IHP  
2.2  
V
I
Input Current when Applying Vilp to P1[0] or P1[1] During  
Programming or Verify  
0.2  
mA  
Driving internal pull-down resistor.  
Driving internal pull-down resistor.  
ILP  
I
Input Current when Applying Vihp to P1[0] or P1[1] During  
Programming or Verify  
1.5  
mA  
IHP  
V
V
Output Low Voltage During Programming or Verify  
Output High Voltage During Programming or Verify  
Vss + 0.75  
Vdd  
V
V
OLV  
Vdd - 1.0  
OHV  
Flash  
Flash  
Flash  
Flash Endurance (per block)  
50,000  
1,800,000  
10  
Erase/write cycles per block.  
Erase/write cycles.  
ENPB  
ENT  
DR  
a
Flash Endurance (total)  
Flash Data Retention  
Years  
a. A maximum of 36 x 50,000 block endurance cycles is allowed. This may be balanced between operations on 36x1 blocks of 50,000 maximum cycles each, 36x2 blocks of  
25,000 maximum cycles each, or 36x4 blocks of 12,500 maximum cycles each (and so forth to limit the total number of cycles to 36x50,000 and that no single block ever  
sees more than 50,000 cycles).  
For the full industrial range, the user must employ a temperature sensor user module (FlashTemp) and feed the result to the temperature argument before writing. Refer to  
the Flash APIs Application Note AN2015 at http://www.cypress.com under Application Notes for more information.  
June 4, 2004  
Document No. 38-12011 Rev. *F  