CY7B933  
mitter BIST loop to run while the Receiver runs in normal  
mode. The BIST loop includes deliberate violation symbols  
and will adequately test the RVS function.  
CY7B933 HOTLink Receiver Operating Mode  
Description  
In normal user operation, the Receiver can operate in either of  
two modes. The Encoded mode allows a user system to send  
and receive 8-bit data and control information without first con-  
verting it to transmission characters. The Bypass mode is  
used for systems in which the encoding and decoding is per-  
formed by an external protocol controller.  
BIST mode is intended to check the entire function of the  
Transmitter (except the Transmitter input pins and the bypass  
function in the Encoder), the serial link, and the Receiver. It  
augments normal factory ATE testing and provides the design-  
er with a rigorous test mechanism to check the link transmis-  
sion system without requiring any significant system overhead.  
In either mode, serial data is received at one of the differential  
line receiver inputs and routed to the Shifter and the Clock  
Synchronization. The PLL in the Clock Synchronizer aligns  
the internally generated bit rate clock with the incoming data  
stream and clocks the data into the shifter. At the end of a byte  
time (ten bit times), the data accumulated in the shifter is trans-  
ferred to the Decode register.  
While in Bypass mode, the BIST logic will function in the same  
way as in the Encoded mode. MODE = HIGH and BISTEN =  
LOW causes the Transmitter to switch to Encoded mode and begin  
sending the BIST pattern, as if MODE = LOW. When BISTEN re-  
turns to HIGH, the Transmitter resumes normal Bypass operation. In  
Test mode the BIST function works as in the Normal mode. For more  
information on BIST, consult the “HOTLink Built-In Self-Test” Applica-  
tion Note.  
To properly align the incoming bit stream to the intended byte  
boundaries, the bit counter in the Clock Synchronizer must be  
initialized. The Framer logic block checks the incoming bit  
stream for the unique pattern that defines the byte boundaries.  
This combinatorial logic filter looks for the X3.230 symbol de-  
fined as “Special Character Comma” (K28.5). Once K28.5 is  
found, the free running bit counter in the Clock Synchronizer  
block is synchronously reset to its initial state, thus “framing”  
the data to the correct byte boundaries.  
Test Mode  
The MODE input pin selects between three transmitter func-  
tional modes. When wired to VCC, the D( ) inputs bypass the  
aj  
Encoder and load directly from the Input register into the Shifter.  
When wired to GND, the inputs D , SVS, and SC/D are encoded  
07  
using the Fibre Channel 8B/10B codes and sequences (shown at the  
end of this datasheet). Since the Transmitter is usually hard wired to  
Encoded or Bypass mode and not switched between them, a third  
function is provided for the MODE pin. Test mode is selected by float-  
ing the MODE pin (internal resistors hold the MODE pin at VCC/2).  
Test mode is used for factory or incoming device test.  
Since noise-induced errors can cause the incoming data to be  
corrupted, and since many combinations of error and legal  
data can create an alias K28.5, an option is included to disable  
resynchronization of the bit counter. The Framer will be inhib-  
ited when the RF input is held LOW. When RF rises, RDY will  
be inhibited until a K28.5 has been detected, and RDY will  
resume its normal function. Data will continue to flow through  
the Receiver while RDY is inhibited.  
Test mode causes the Transmitter to function in its Encoded  
mode, but with OutA+/OutB+ (used as a differential test clock  
input) as the bit rate clock input instead of the internal  
PLL-generated bit clock. In this mode, inputs are clocked by  
CKW and transfers between the Input register and Shifter are  
timed by the internal counters. The bit-clock and CKW must  
maintain a fixed phase and divide-by-ten ratio. The phase and  
pulse width of RP are controlled by phases of the bit counter (PLL  
feedback counter) as in Normal mode. Input and output patterns can  
be synchronized withinternal logicbyobservingthe state of RP or the  
device can be initialized to match an ATE test pattern using the follow-  
ing technique:  
Encoded Mode Operation  
In Encoded mode the serial input data is decoded into eight  
bits of data (Q Q ), a context control bit (SC/D), and a system  
0
7
diagnostic output bit (RVS). If the pattern in the Decode register is  
found in the Valid Data Characters table, the context of the data is  
decoded as normal message data and the SC/D output will be  
LOW. If the incoming bit pattern is found in the Valid Special Char-  
acter Codes and Sequences table, it is interpreted as “control” or  
“protocol information,” and the SC/D output will be HIGH. Special  
characters include all protocol characters defined for use in packets  
for Fibre Channel, ESCON, and other proprietary and diagnostic  
purposes.  
1. With the MODE pin either HIGH or LOW, stop CKW and  
bit-clock.  
2. Force the MODE pin to MID (open or V /2) while the  
CC  
clocks are stopped.  
3. Start the bit-clock and let it run for at least 2 cycles.  
4. Start the CKW clock at the bit-clock/10 rate.  
The Violation symbol that can be explicitly sent as part of a  
user data packet (i.e., Transmitter sending C0.7; D  
= 111  
70  
00000 and SC/D = 1; or SVS = 1) will be decoded and indicated in  
exactly the same way as a noise-induced error in the transmission  
link. This function will allow system diagnostics to evaluate the error  
in an unambiguous manner, and will not require any modification to  
the receiver data interface for error-testing purposes.  
Test mode is intended to allow logical, DC, and AC testing of  
the Transmitter without requiring that the tester check output  
data patterns at the bit rate, or accommodate the PLL lock,  
tracking, and frequency range characteristics that are required  
when the HOTLink part operates in its normal mode. To use  
OutA+/OutB+ as the test clock input, the FOTO input is held  
HIGH while in Test mode. This forces the two outputs to go to  
an “PECL LOW,” which can be ignored while the test system  
creates a differential input signal at some higher voltage.  
Bypass Mode Operation  
In Bypass mode the serial input data is not decoded, and is  
transferred directly from the Decode register to the Output reg-  
ister’s 10 bits (Q( ). It is assumed that the data has been pre-en-  
aj  
coded prior to transmission, and will be decoded in subsequent log-  
ic external to HOTLink. This data can use any encoding method  
suitable to the designer. The only restrictions upon the data encod-  
ing method is that it contain suitable transition density for the Receiv-  
18  