PRELIMINARY  
CYW43340  
7.2 UART Interface  
The CYW43340 uses a UART for Bluetooth. The UART is a standard 4-wire interface (RX, TX, RTS, and CTS) with adjustable baud  
rates from 9600 bps to 4.0 Mbps. The interface features an automatic baud rate detection capability that returns a baud rate selection.  
Alternatively, the baud rate may be selected through a vendor-specific UART HCI command.  
The UART has a 1040-byte receive FIFO and a 1040-byte transmit FIFO to support EDR. Access to the FIFOs is conducted through  
the AHB interface through either DMA or the CPU. The UART supports the Bluetooth 4.0 UART HCI specification: H4 and H5. The  
default baud rate is 115.2 Kbaud.  
The UART supports the 3-wire H5 UART transport, as described in the Bluetooth specification (“Three-wire UART Transport Layer”).  
Compared to H4, the H5 UART transport reduces the number of signal lines required by eliminating the CTS and RTS signals.  
The CYW43340 UART can perform XON/XOFF flow control and includes hardware support for the Serial Line Input Protocol (SLIP).  
It can also perform wake-on activity. For example, activity on the RX or CTS inputs can wake the chip from a sleep state.  
Normally, the UART baud rate is set by a configuration record downloaded after device reset, or by automatic baud rate detection,  
and the host does not need to adjust the baud rate. Support for changing the baud rate during normal HCI UART operation is included  
through a vendor-specific command that allows the host to adjust the contents of the baud rate registers. The CYW43340 UARTs  
operate correctly with the host UART as long as the combined baud rate error of the two devices is within ±2% (see Table 12).  
Table 12. Example of Common Baud Rates  
Desired Rate  
Actual Rate  
Error (%)  
4000000  
3692000  
3000000  
2000000  
1500000  
1444444  
921600  
460800  
230400  
115200  
57600  
4000000  
3692308  
3000000  
2000000  
1500000  
1454544  
923077  
461538  
230796  
115385  
57692  
0.00  
0.01  
0.00  
0.00  
0.00  
0.70  
0.16  
0.16  
0.17  
0.16  
0.16  
0.00  
0.16  
0.00  
0.16  
0.00  
38400  
38400  
28800  
28846  
19200  
19200  
14400  
14423  
9600  
9600  
Document Number: 002-14943 Rev. *L  
Page 30 of 96  