CYW20732A0
3.2 RF Specifications
Table 16. Receiver RF Specifications
Parameter
Receiver Sectiona
Mode and Conditions
Min
2402
Typ
Max
2480
Unit
MHz
Frequency range
–
–
RX sensitivity (standard)
RX sensitivity (low current)
Input IP3
0.1%BER, 1Mbps, dirty transmitter OFF
–
–93
–90
–
–
–
–
–
dBm
dBm
dBm
dBm
–
–
–
–16
–10
Maximum input
–
Interference Performancea,b
C/I cochannel
0.1%BER
0.1%BER
0.1%BER
0.1%BER
0.1%BER
0.1%BER
–
–
–
–
–
–
–
–
–
–
–
–
21
dB
dB
dB
dB
dB
dB
C/I 1 MHz adjacent channel
C/I 2 MHz adjacent channel
C/I 3 MHz adjacent channel
C/I image channel
15
–17
–27
–9.0
–15
C/I 1 MHz adjacent to image channel
Out-of-Band Blocking Performance (CW)a,b
30 MHz to 2000 MHz
2003 MHz to 2399 MHz
2484 MHz to 2997 MHz
3000 MHz to 12.75 GHz
Spurious Emissions
30 MHz to 1 GHz
0.1%BERc
–
–
–
–
–30.0
–35
–
–
–
–
dBm
dBm
dBm
dBm
0.1%BERd
0.1%BERd
0.1%BERe
–35
–30.0
–
–
–
–
–
–
–57.0
–55.0
dBm
dBm
1 GHz to 12.75 GHz
a.30.8% PER.
b.Desired signal is 3 dB above the reference sensitivity level (defined as –70 dBm).
c. Measurement resolution is 10 MHz.
d. Measurement resolution is 3 MHz.
e. Measurement resolution is 25 MHz.
Document Number: 002-14837 Rev. *L
Page 23 of 35