CY7C1359A/GVT71256T18
Electrical Characteristics Over the Operating Range
Parameter
VIHD
VIH
Description
Input High (Logic 1) Voltage[15, 21]
Test Conditions
Data Inputs (DQxx)
Min.
1.7
1.7
–0.3
–2
Max.
Unit
V
VCC+0.3
All Other Inputs
4.6
0.8
2
V
VIl
Input Low (Logic 0) Voltage[15, 21]
Input Leakage Current[22]
Output Leakage Current
V
ILI
0V < VIN < VCC
µA
µA
V
ILO
Output(s) disabled, 0V < VOUT < VCC
IOH = –4.0 mA at VCCQ = 3.135V
IOH = –4.0 mA at VCCQ = 2.375V
IOL = 8.0 mA
–2
2
VOH
VOH
VOL
Output High Voltage[15, 23]
2.4
1.7
Output Low Voltage[15, 23]
Supply Voltage[15]
I/O Supply Voltage[15]
0.4
3.6
V
V
V
VCC
3.135
2.375
VCCQ
VCC
166
150
133
100
MHz/ MHz/ MHz/ MHz/
Parameter
Description
Conditions
Typ.
-6
-6.7
-7.5
-10
Unit
ICC
Power Supply
Current:
Device selected; all inputs < VILor > VIH;
cycle time > tKC min.; VCC = Max.;
outputs open
100
310
275
250
190
mA
Operating[24, 25, 26]
ISB2
ISB3
ISB4
CMOS Standby[25, 26] Device deselected; VCC = Max.;
all inputs < VSS + 0.2 or > VCC – 0.2;
5
10
20
80
10
20
70
10
20
60
10
20
50
mA
mA
mA
all inputs static; CLK frequency = 0
TTL Standby[25, 26]
Device deselected; all inputs < VIL
or > VIH; all inputs static;
10
40
VCC = Max.; CLK frequency = 0
Clock Running[25, 26] Device deselected;
all inputs < VIL or > VIH; VCC = Max.;
CLK cycle time > tKC min.
Capacitance[17]
Parameter
Description
Test Conditions
Typ.
Max.
Unit
CI
Input Capacitance
Input/Output Capacitance (DQ)
TA = 25°C, f = 1 MHz,
4
7
5
8
pF
pF
VCC = 3.3V
CO
Thermal Resistance
Description
Test Conditions
Symbol BGA Typ. TQFP Typ. Unit
Thermal Resistance (Junction to Ambient) Still Air, soldered on a 4.25 x 1.125 inch,
ΘJA
ΘJC
19
9
25
9
°C/W
°C/W
4-layer PCB
Thermal Resistance (Junction to Case)
Note:
21. Overshoot: VIH ≤ +6.0V for t ≤ tKC /2.
Undershoot:VIL ≤ –2.0V for t ≤ tKC /2.
22. MODE pin has an internal pull-up and ZZ pin has an internal pull-down. These two pins exhibit an input leakage current of ±30 µA.
23. AC I/O curves are available upon request.
24. ICC is given with no output current. ICC increases with greater output loading and faster cycle times.
25. “Device Deselected” means the device is in Power-Down mode as defined in the truth table. “Device Selected” means the device is active.
26. Typical values are measured at 3.3V, 25°C, and 8.5-ns cycle time.
Document #: 38-05120 Rev. **
Page 15 of 24