Crane Aerospace & Electronics Power Solutions
MHV Single, Dual and Triple DC/DC Converters
28 VOLT INPUT – 15 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
MHV283R3S
MHV2805S
MIN TYP MAX
4.95 5.00
MHV2812S
MIN TYP MAX
11.88 12.00 12.12 14.85 15.00 15.15
MHV2815S
PARAMETER
CONDITIONS
MIN TYP MAX
MIN TYP
MAX
UNITS
VDC
A
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
3.27 3.30
3.33
3.03
10
5.05
3.0
15
V
V
= 16 to 50 VDC
= 16 to 50 VDC
0
0
—
—
0
0
—
—
0
0
—
—
1.25
15
0
0
—
—
1.0
15
IN
IN
W
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
10 kHz - 2 MHz
Tc = –55°C to +125°C
= 16 to 50 VDC
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 120 ms
NO LOAD
—
—
—
16
5
0
15
25
8
30
—
—
—
16
5
0
15
25
8
40
—
—
—
16
5
1
8
25
10
30
50
—
—
—
16
5
4
10
25
13
35
50
mV p-p
mV
mV
V
IN
28
50
28
50
28
28
VDC
1
—
—
—
—
34
8.4
80
42
10
—
—
—
—
44
8.4
80
52
10
—
—
—
—
43
8.4
75
55
10
—
—
—
—
45
8.4
60
62
10
V
mA
mA
INHIBITED
10 kHz - 20 MHz
Tc = –55°C to +125°C
INPUT RIPPLE
CURRENT
—
69
10
72
45
—
—
74
10
77
40
—
—
79
10
81
40
—
—
78
10
81
40
—
mA pp
%
EFFICIENCY
2
LOAD FAULT
POWER DISSIPATION
SHORT CIRCUIT
2
—
—
—
—
7
20
—
—
—
—
8
20
—
—
—
—
7
20
—
—
—
—
7
20
W
ms
1
RECOVERY
STEP LOAD
RESPONSE
50% – 100% – 50%
TRANSIENT
RECOVERY
DELAY
3
—
—
—
—
—
—
14
0
300
1
18
—
—
—
—
—
—
14
0
300
1.5
18
—
—
—
—
—
—
14
0
350
1.3
18
—
—
—
—
—
—
14
0
450
1.3
18
mV pk
mS
ms
START-UP
0 TO 28 V
STEP LINE
RESPONSE
OVERSHOOT
100
100
120
150
mV pk
IN
4
16-50-16 VDC
1
TRANSIENT
175
0.9
200
550
2
200
550
2.5
200
650
2.5
200
mVpk
mS
μF
4
RECOVERY
1
CAPACITIVE LOAD
Notes
1. Guaranteed by design, not tested.
2. Load fault is a short circuit (<50 mΩ). Recovery is into a resistive load.
3. Load step transition ≥ 10 μs. Recovery = time to settle to within 1% of Vout final value.
4. Input step transition ≥ 10 μs. Recovery = time to settle to within 1% of Vout final value.
www.craneae.com
Page 6 of 14
Rev D- 20060710