Crane Aerospace & Electronics Power Solutions
MHV Single, Dual and Triple DC/DC Converters
28 VOLT INPUT – 15 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
TRIPLE OUTPUT MODELS
PARAMETER
MHV28512T
TYP
MHV28515T
TYP
CONDITION
MAIN
+ AUXILIARY
– AUXILIARY
MAIN
+ AUXILIARY
– AUXILIARY
TOTAL
MAIN
+ AUXILIARY
MIN
4.95
11.88
11.82
0
MAX
5.05
MIN
4.95
14.85
14.77
0
MAX
5.05
UNITS
OUTPUT VOLTAGE
5.0
5.0
12.0
12.12
12.18
2.0
15.0
15.15
15.23
2.0
VDC
12.0
15.0
2
OUTPUT CURRENT
IN
—
—
V
= 16 TO 50
—
0.208
0.333
—
0.167
0.267
A
—
—
—
—
—
—
—
—
—
—
0.208
0.333
2.416
10
4
4
—
—
—
—
—
—
—
—
—
—
0.167
0.267
2.333
10
4
4
—
—
3
OUTPUT POWER
= 16 TO 50
—
—
V
—
—
IN
W
– AUXILIARY
---
—
8
_
—
8
TOTAL
15
22
22
5
15
22
22
5
OUTPUT RIPPLE
VOLTAGE Tc= -55° to +125°C 10 kHz to 2 MHz
LINE REGULATION MAIN
= MIN. TO MAX. +AUXILIARY
10 kHz to 2 MHz
MAIN
mV p-p
mV
AUXILIARY
9
9
0
0
V
5
35
7
35
IN
– AUXILIARY
—
—
—
—
—
16
—
7
10
10
40
400
28
—
40
—
—
—
—
—
16
—
7
10
10
40
400
28
—
40
LOAD REGULATION
MAIN
20
20
+AUXILIARY
– AUXILIARY
30
70
800
50
80
30
80
800
50
80
mV
4
CROSS REGULATION
- AUXILIARY CONDITION A & B
CONTINUOUS
mV
1
INPUT VOLTAGE
VDC
TRANSIENT 120 ms
INPUT CURRENT
NO LOAD
INHIBITED
—
—
30
8.4
37
10
—
—
34
8.4
41
10
mA
INPUT RIPPLE CURRENT
Tc= -55° to +125°C
EFFICIENCY
10 kHz to 10 MHz
—
10
30
—
10
30
mA p-p
%
76
—
—
---
—
78
—
—
---
—
—
9
9
75
—
—
---
—
78
—
—
---
—
—
9
9
LOAD FAULT /
SHORT CIRCUIT
POWER DISSIPATION
MAIN
W
4
AUXILIARY
RECOVERY - EACH OPUTPUT
25
250
25
250
mS
mV
6, 7
TRANSIENT
MAIN
STEP LOAD RESPONSE
AUXILIARY
—
—
—
—
---
---
---
---
—
—
—
7
550
—
—
—
—
---
---
---
---
—
—
—
7
550
RECOVERY
MAIN
2.5
2.5
ms
ms
AUXILIARY
3.5
3.5
7
START-UP
DELAY EACH OUTPUT
OVERSHOT
15
15
MAIN
---
---
---
---
100
240
200
100
---
---
---
---
100
300
200
100
AUXILIARY
mV pk
μF
1
CAPACITIVE LOAD
MAIN˜
AUXILIARY
TRANSIENT
7
1
STEPLINE RESPONSE
MAIN
—
—
400
—
—
400
mV pk
mS
AUXILIARY
—
—
—
—
—
—
500
—
—
—
—
—
—
500
1
RECOVERY
MAIN
3
3
AUXILIARY
4
4
Notes
1. Guaranteed by design, not tested.
A. Positive aux. = 2.5 W; -(50%) negative aux. = 2.5 W to 0.5 W (50% to 10%).
B. From +Po = 70% and -Po = 30% to + Po = 30% and -Po =70%.
Above conditions are referenced to 50%/50% balanced loads.
2. The sum of the 12 volt auxiliary output currents may not exceed 416 mA.
The sum of the 15 volt auxiliary output currents may not exceed 333 mA.
3. The sum of the auxiliary output power may not exceed 5 watts.
5. Load fault is a short circuit (<50 mΩ). Recovery is into a resistive load.
4. Cross regulation occurs between the two auxiliaries and is measured on –aux. +5 is held 6. Load step transition ≥ 10 μs. Recovery = time to settle to within 1% of Vout final value.
constant at 2.0 A. Cross regulation is specified for two conditions:
7. Input step transition ≥ 10 μs. Recovery = time to settle to within 1% of Vout final value.
www.craneae.com
Page 8 of 14
Rev D- 20060710