3.0 Registers  
CX28394/28395/28398  
3.3 Primary Control and Status Register  
Quad/x16/OctalT1/E1/J1 Framers  
RFRAME[3:0]  
Receiver Framer Mode—Establishes the offline framer's search criteria for recovery of frame  
alignment (reframe). Also works in conjunction with the RLOFA–RLOFD bits [addr 040] to  
establish the online framer's criteria for loss of frame alignment. Refer to Tables A-1 through  
A-6 to find which frame bits are monitored and Table 2-2, Criteria for Loss/Recovery of  
Receive Framer Alignment, for frame alignment loss/recovery criteria during the selected  
mode. Mode descriptions are given in Table 3-5. Online framers SF, SLC, CAS and MFAS  
criteria for loss/recovery of multiframe alignment are also selected by RFRAME[3:0].  
Table 3-5. Receive Framer Modes  
RFRAME[3:0]  
T1/E1N  
Receive Framer Mode  
000X  
001X  
010X  
011X  
100X  
101X  
110X  
111X  
0000  
0001  
0100  
0101  
0110  
1000  
1001  
1100  
1101  
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
FAS Only  
FAS Only + BSLIP  
FAS + CRC  
FAS + CRC + BSLIP  
FAS + CAS  
FAS + CAS + BSLIP  
FAS + CRC + CAS  
FAS + CRC + CAS + BSLIP  
FT Only  
ESF + No CRC (FPS only)  
SF  
SF + JYEL  
SF + T1DM  
SLC + FSLOF  
SLC  
ESF + Mimic CRC  
ESF + Force CRC  
T1/E1N  
Global T1/E1 Select—Affects all functions by enabling receive and transmit circuits to operate  
at either the T1 or E1 line rate. The processor should reinitialize all control register settings  
after changing the T1/E1N control bit. T1/E1N selects the nominal line rate (shown below)  
while the exact receive and transmit line rate frequencies are independently determined by  
their respective input clock or input data references. The actual receive and transmit line  
frequency can vary within defined tolerances.  
0 = 2.048 MHz line rate (E1)  
1 = 1.544 MHz line rate (T1)  
3-12  
Conexant  
100054E  
 