High Speed GMSK Modem 4k to 64kbps  
Page 8 of 20  
MX589  
The output of the radio receiver's Frequency Discriminator should be fed to the MX589's RX Filter by a  
suitable gain and DC level adjusting circuit. This circuit can be built with external components around the on-  
chip RX Input Amplifier. The gain should be set so that the signal level at the RX Feedback pin is nominally  
1V peak to peak (for VDD=5.0V) centered around VBIAS when receiving a continuous 1111000011110000..  
data pattern.  
Positive going signal excursions at RX Feedback pin will produce a logic 0 at the RX Data Output. Negative  
going excursions will produce a logic 1.  
The received signal is fed through the lowpass RX Filter, which has a -3dB corner frequency of 0.56 times the  
data bit-rate, before being applied to the Level Measure and Clock and Data extraction blocks.  
The Level Measuring block consists of two voltage detectors, one of which measures the amplitude of the  
positive parts of the received signal. The other measures the amplitude of the negative portions. (Positive  
refers to signal levels higher than VDD/2, and negative to levels lower than VDD/2.) External capacitors are  
used by these detectors, via the Doc1 & Doc2 pins, to form voltage ‘hold’ or ‘integrator’ circuits. These two  
levels are then used to establish the optimum DC level decision-thresholds for the Clock and Data extraction,  
depending upon the RX signal amplitude and any DC offset.  
4.2.2 Rx Circuit Control Modes  
The operating characteristics of the Rx Level Measurement and Clock Extraction circuits are controlled, as  
shown in Table 5, by logic level inputs applied to the PLLacq, Rx HOLD , and RxDCacq pins to suit a  
particular application, or to cope with changing reception conditions, reference Figure 5.  
In general, a data transmission will begin with a preamble, for example, 1100110011001100, to allow the  
receive modem to establish timing and level-lock as quickly as possible. After the Rx carrier has been  
detected, and during the time that the preamble is expected, the RxDCacq and PLLacq Inputs should be  
switched from a logic 0 to a logic 1 so that the Level Measuring and Clock Extraction modes are operated and  
sequenced as shown.  
The Rx HOLD input should normally be held at a logic 1 while data is being received, but may be driven to a  
logic 0 to freeze the Level Measuring Clock Extraction circuits during a fade. If a fade lasts for less than 200  
bit periods, normal operation can be resumed by returning the Rx HOLD input to a logic 1 at the end of the  
fade. For longer fades, it may be better to reset the Level Measuring circuits by placing the RxDCacq to a  
logic 1 for 10 to 20 bit periods.  
Rx HOLD has no effect on the Level Measuring circuits while RxDCacq is at a logic 1, and has no effect on  
the PLL while PLLacq is at a logic 1.  
A logic 0 on Rx HOLD does not disable the Rx Clock output, and the Rx Data Extraction and S/N Detector  
circuits will continue to operate.  
PREAMBLE  
DATA  
Rx Signal Input  
Rx CARRIER DET  
(RSSI) Input  
RxDCacq  
Rx LEVEL MEASURE  
MODE  
FAST PEAK  
DETECT  
AVERAGING PEAK  
DETECT  
CLAMP  
PLLacq  
CLOCK EXTRACTION  
CCT MODE  
30 BITS  
MEDIUM  
ACQUIRE  
NARROW  
BANDWIDTH  
BANDWIDTH  
Figure 5: Rx Mode Control Diagram  
2001 MX-COM, Inc.  
www.mxcom.com tel: 800 638 5577 336 744 5050 fax: 336 744 5054  
Doc. # 204800103.011  
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA  
All trademarks and service marks are held by their respective companies.  
 复制成功!